38
Check the water inlet filter regularly. Power off the machine, turn the filter knob anticlockwise, then take out the filter,
use laundry powder and brush to clean the filter, then install back to the pump, fix the knob till no water leak out
Note: Before testing the machine, make sure the axis center of the pump and motor must be on the same line.
Adjust the pressure adjust knob is not allowed
5)
Coolant flow test
If machine display coolant flow false alarm(060),shall refer to Coolant flow sensor maintenance and do one
maintenance.After done,if system still display coolant flow fault alarm,shall further check and find the cause of trouble
shooting.
8. Maintenance
Wearing parts life become short is the plasma system problem, the short life of spare will increase the cost.
1
、
Cutting machine
⑴
Dismantle the side and top cover once a month, use dry compressed air to flow away dust
⑵
Check the cutting machine cable regularly to check if have damage or loss. If the cable color fade, it may because of
overheat, please replace
⑶
Check the contactor regularly, check the connection is corrosive or not, if the surface is black and hard, please replace
2
、
Cooling system
⑴
Replace the coolant regularly(6 month or 300 hours
⑴
Check the coolant flow regularly, add if need
⑵
Check the coolant filter under the cutting machine front panel, clean and replace if need
⑶
Turn on the machine but not cut, check if have coolant leak: the inlet and outlet connector at back of the cutting
machine, HF box torch connection parts and water tube connection parts and torch
3
、
Gas supply system
Check each gas hose, process as following:
⑴
Remove all the input gas hose install parts of gas console, use plug to choke
⑵
Increase pressure of the hose to 0.83MPa
⑶
Shut off the gas valve, check the gas pressure to see if decrease, if decrease need to check where gas leak
⑷
Check each gas hose according to step 3
⑸
Test the gas leak according to the test process
⑹
Check all the hose, make sure there is no twist or damage
Note: the gas system maintenance must check everyday when use the flammable gas
4
、
Arc initiator
⑴
Open the cover, use compressed air to flow away the dust, if have water, need clean with cloth, and find out the water
source
⑵
Check the HF ignition to see if corrosion
5
、
Ground connection
⑴
Make sure all the parts of the system connect ground safety.
⑵
Make sure the workpiece ground connect well, especially the workpiece cable and CNC table connect well, it must be
clean and connect well
Содержание SLG-200HF
Страница 1: ...SLG 200 300 400HF PLASMA CUTTING MACHINE MANUAL INSTRUCTION PLEASE READ IT CAREFULLY BEFORE OPERATION...
Страница 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...