12
3. Secondary menu
Press gas check knob for 5s, come into secondary menu model, digital meter show the secondary menu code
Turn the encoder, adjust the secondary menu code
(
P01
~
P12
)
, press display knob for confirmation, digital meter
show parameter
Turn encoder, adjust parameter value, press display knob for confirmation, storage the parameter, digital meter show
back to up step menu code
Press gas check knob for 5s, withdraw from secondary menu model,or after 30s without any operation, it will
automatically withdraw from the secondary menu mode
Secondary menu parameter back to factory set: come into the secondary menu mode, press display knob for 5s, all
P01
~
P12 parameter back to factory set. After that, all indicator on panel on for 1.5s, then off 0.5s, then come to normal,
machine is under operation
Secondary menu code function and parameter table 4-1
。
Code
Function
Parameter Unit
Default
value
Function description
P01
Set gas pre flow
time
0.20
~
5.00
S
1.10
Power on the machine, set this time before arc strike
P02
Set gas post flow
time
5
~
100
S
10
The gas blow time after arc off
P03
Set current up slope
time
0.10
~
1.00
S
0.15
After arc strike success, the exact current will up to the
set value
P04
Set cutting time
1
~
999
Min
999
Set the torch consumables cutting time
After set, the related P06 value will upgrade accordingly
P05
Set penetration
times
1
~
999
time
999
Set the torch consumables penetration times
After set, the related P07 value will upgrade accordingly
P06
Check left cutting
time
-
Min
-
Check the torch consumables left cutting time
P07
Check left
penetration times
-
time
-
Check the torch consumables penetration times
P08
Set monitoring
control switch
0 or 1
-
0
When cutting time or penetration times reaches set
value, machine alarm:
0
:
After alarm, machine can still cutting
1
:
After alarm, machine can’t cutting
P09
Monitoring
parameter reset
0 or 1
-
0
0
:
Keep the present cutting time and penetration times
calculation
1
:
The cutting time and penetration times become 0
P10
Set monitoring
alarm function
0 or 1
-
0
0
:
Shut off the alarm function, not calculate the cutting
time or penetration times
1
:
Turn on the alarm function, calculate the cutting time
and penetration times, when any of item reach the set
value, machine alarm 085
P11
Set digital
communication
address
1
~
63
-
1
Digital communication address
P12
Set digital
communication
switch
0 or 1
-
0
0
:
Shut off the communication function
1
:
Turn on the communication function
Содержание SLG-200HF
Страница 1: ...SLG 200 300 400HF PLASMA CUTTING MACHINE MANUAL INSTRUCTION PLEASE READ IT CAREFULLY BEFORE OPERATION...
Страница 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Страница 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Страница 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Страница 48: ...41 7 2 SLG 300HF...
Страница 49: ...42 7 3 SLG 400HF...
Страница 50: ...43 7 4 QFK E1...