36
LED code
Indicator function
Instruction
LED19
Stop signal
Machine receive stop signal,LED19 on
LED20
—
Reservation
LED21
Plasma big valve control
Turn on the plasma big valve YV3
,
LED21 on
LED22
Plasma small valve control
Turn on the plasma small valve YV2
,
LED22 on
LED23
Main circuit cooling fan control
Turn on main circuit cooling fan, LED23 on
LED24
Cooling system power supply
Turn on the cooling system control signal, LED24 on
LED25
HF control
HF start, LED25 spark
LED26
Board PL03 +15V1 voltage lack
PL03 +15V1 lack voltage
,
LED26 on
LED27
Shield gas value control
Open this shield gas value YV1
,
LED27 on
LED28
Plasma gas pressure inspect
Plasma gas pressure normal, LED28 on
LED29
Shield gas pressure inspect
Shield gas pressure normal, LED29 on
LED30
Arc strike success signal
After arc strike and cutting, LED30 on
LED31
Main machine temperature
inspect
Temperature normal,LED31 on
LED32
Deputy machine temperature
inspect
Temperature normal,LED32 on(SLG-200HF no this function)
LED34
Abnormal alarm signal
When there is error appear,LED34 on, the alarm signal output from X5
at back of the machine.
2)
PL02
LED code
Indicator function
Instruction
D1
Cooling system power supply
Power supply,D1 on
D2
Main circuit cooling fan power supply
Power supply,D2 on
D3
HF control
HF start,LED25 spark
5. Initial inspection
Before checking trouble shooting,must check the outside of power source,check the fuse,IGBT module,diode module
and PCB parts whether damaged.
1
、
Turn off main switch,shut off power source.
2
、
Check the 4 fuse back of machine whether fused.
3
、
Connect main switch,measure any two phase of the three phase inlet interface voltage,any two phase voltage shall as
same as power supply voltage.If found problem here,turn off main switch,check inlet power cable circuit.
3
、
Take out the top cover and two side covers.
4
、
Check the inside power source,ex. PCB whether have color changes as burned,or whether parts have been explored.If
found these parts or module have obviously phenomenon,shall replace all broken parts before do any test.
6. Air filter cartridge replace
Recommend users regular replace air filter cartridge,the steps as follows:
1
、
Cut off all power supply and disconnect the air tube to air filter.
2
、
Strike the filter cup.
Содержание SLG-200HF
Страница 1: ...SLG 200 300 400HF PLASMA CUTTING MACHINE MANUAL INSTRUCTION PLEASE READ IT CAREFULLY BEFORE OPERATION...
Страница 12: ...5 3 2 SLG 300HF dimension and weight 3 3 SLG 400HF dimension and weight...
Страница 22: ...15 5 2 Installation Drawing System components A Plasma power sourceSLG 200HF 300HF 400HF...
Страница 47: ...40 3 Circuit diagram 7 1 SLG 200HF...
Страница 48: ...41 7 2 SLG 300HF...
Страница 49: ...42 7 3 SLG 400HF...
Страница 50: ...43 7 4 QFK E1...