6. List of Manufacturer Parameters
Parameter Item
Initial
Value
Function
System
Parameters
Air End 2
Time
000000 hrs
Modify the total running time of Air End 2.
Fault History
Reset
0000
Enter "8888" and confirm it to clear the fault
history.
Temperature
2
Warning
105
℃
When Air End 2 temperature is higher than this set
temperature, a warning will be given.
Temperature
2
Shutdown
110
℃
When Air End 2 temperature is higher than this set
temperature, fault shutdown will be reported.
Date
9999-99-99
Record the manufacture date of air compressor.
Manufacture
Number
99999999
Manufacture number of equipment entered by
manufacturer.
Phase
Sequence
Protection
Disable /
Enable
Used to disable or enable the phase sequence
protection.
Frequency
Selection
50Hz/60Hz
Select the working power frequency of air
compressor. If set incorrectly, there will be a
deviation in detected current value.
Connection
Method
Advanced /
Compatible
Alternate
High Voltage
0000V
When the controller detects that the voltage is
higher than the set value, the machine will shut
down for protection and a higher voltage is
reported. When set to 0000, the high-voltage
function is invalid.
Low Voltage
0000V
When the controller detects that the voltage is
lower than the set value, the machine will shut
down for protection and a lower voltage is
reported. When set to 0000, the low-voltage
function is invalid.
Low
Temperature
Protection
-0005
℃
When the controller detects that the exhaust
temperature is lower than this value, it shows the
temperature is too low, and the air compressor is
not allowed to start.
Time Limit
0000 hrs
When the air compressor has run for a time greater
than the set time, it will shut down with a report of
"use error"; when set to 0000, the time limit
function is invalid.