U8185
Maintenance Manual
9 Principles and Failure Analysis
Issue 1.0 (2012-03-23)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54
Figure 9-21
Vibration failure
Vibration failure
Re-install the software. Problem
solved?
Y
N
Is the motor not soldered properly?
Re-solder the motor
and verify its function
End
Y
N
End
Is the motor pad’s power supply equal
to the battery voltage? When the
motor test starts, is the negative
electrode of the motor at low level?
The power supply is
normal. Further
analysis is required.
Y
N
Replace the motor. Problem solved?
End
Y
N
Send the phone to an
advanced service site for
repair
Table 9-4
Circuit diagram signal summary
Signal
Description
Reference Measurement
or Wave Form
VPH_PWR
Main power supply, supplying power
to the motor
None.
VI B_DRV_N
Motor drive signal pin, connected to
the motor's negative electrode
None.
9.4.4 Voice Reception
Figure 9-22
Circuit schematic diagram