10 Maintenance
Issue 02 (2014-03-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
112
If any of the items does meet the requirements, power off the endpoint and take measures to
improve the environment. Ensure that the endpoint is used only when all the listed items meet
the requirements.
Table 10-1
Checking the working environment
Item
Requirement
Operating temperature
0°C to 40°C
Operating humidity
10% to 80% RH
10.2 Checking the Endpoint Periodically
For preventive maintenance purposes, you need to check the audio, video, and communication
cables periodically.
Periodically (once a week is recommended) check that the cables connecting peripheral
equipment and the power supply to the endpoint are securely connected.
Periodically (once a week is recommended) check whether the communication cables
connected to the endpoint work properly.
Power on the endpoint and call some other endpoints using different methods, such as
calling over a broadband network. If a call cannot be set up, verify that the cables are
connected correctly and securely and the communication parameters are set correctly. If
the problem persists, contact the videoconferencing network administrator to check the
network.
10.3 Viewing System Status
Knowing system status at any given time helps to better maintain the endpoint.
Use any of the following methods to access the
Status
screen and view system status:
Press
on the remote control and select
Status
.
Select
from the option bar.
Choose
Advanced
>
Diagnostics
>
Status
.
The following information is displayed on the
Status
screen:
Line status: includes the local IP addresses and network port modes of LAN1 and LAN2,
MAC address, WLAN IP address, whether to enable the GK, H.323 site number, whether
to enable SIP, SIP site number, whether to connect 4 x E1 lines, and camera status and
uptime.