25
Parameter
Description
Off-grid mode
If this parameter is set to Enable, the ESS switches to the off-grid mode
when the grid fails.
Backup power SOC
Sets the backup power SOC. In grid-tied mode, the battery does not
discharge when it is discharged to the backup power SOC. When the grid
fails, loads are powered in backup mode.
Grid-tied/Off-grid
mode switching
If this parameter is set to Automatic switching, the system switches to the
off-grid mode when the grid fails, and switches to the grid-tied mode when
the grid recovers.
Voltage in
independent
operation
Select the voltage in independent operation based on the inverter cable
connection, 101 V or 202 V.
Creating a Plant
7.3.4
After the connection management status on the SmartLogger WebUI is successful, log in to the
FusionSolar app and create a PV plant.