Please connect the the cabinet to the grounding terminals of the VIS6000 with the grounding cable in the
material list of the VIS6000. The grounding cables are wired on the right of the rear of the cabinet.
b
Fix the Grounding Cable to
the VIS6000
c
Fasten the Grounding Cable
a
Use a Cross Screwdriver to Loosen the Nut of the Grounding
Clip
2 Connecting the Other End of the Grounding Cable
to the Grounding Terminal of the Cabinet
The N610E-22 cabinet is installed with grounding cables. You can remove
the grounding cables and then install the grounding cables in the material list
of the VIS6000 to the cabinet.
Before connecting the grounding cable to the cabinet grounding end, check
whether the cabinet grounding end is covered by insulation paint. If the
cabinet grounding end is covered by insulation paint, scrape the paint off,
and then connect the grounding cable to the cabinet grounding end. If the
grounding end is not covered by insulation paint, connect the grounding
cable directly to the cabinet grounding end. After connecting the grounding
cable to the cabinet, use a multimeter to check whether the device is
grounded correctly. If the device is grounded correctly, execute the
operations in the following sections.