cs0_csr54 = 11882
cs0_csr63 = 0
cs1_csr2 = 0 (success)
cs1_csr_51 = 0 (success)
cs1_csr54 = 6254
cs1_csr63 = 529
dsclk_csr0 = 0 (success)
dsclk_csr24 = 0 (success)
dsclk_csr27 = 38352
tx_csr2 = 180
tx_csr26 = 51100
rx_csr10 = 180
rx_csr26 = 24703
rx_csr61 = 6164
tx_csr_rw_result = 0 (success)
rx_csr_rw_result = 0 (success)
tx_csr48 = 49163
rx_csr10 = 1
eye_top = 15
......
6.1.4.25 Querying Optical Module Information of a Specified Port (sfp)
Function
The
sfp
command is used to query optical module information of a port.
Format
hinicadm sfp -i
<
devicename
>
-p
<
portid
> [
-a
]
Parameters
Parameter
Description
Value
devicename
Indicates the name of the
IN200 to be queried in the
system.
Example:
hinic0
or
hinic1
portid
Indicates the number of a port
to be queried.
This parameter takes effect when
type
is
set to
1
.
Usage Instruction
If the command contains
-a
, all information about the optical module is displayed in
hexadecimal format.
Example
# Queries optical module information of port 0.
[root@localhost tool]#
hinicadm sfp -i hinic0 -p 0
--------------------show sfp info--------------------
ucId = 0x03
ucIdExt = 0x04
ucConnector = 0x21
ucEncoding = 6
ucBrNominal = 255 (100MBd)
Huawei IN200 NIC
User Guide
6 Management Tools
Issue 06 (2019-07-27)
Copyright © Huawei Technologies Co., Ltd.
87