Format
hinicadm pdm -i
<
devicename
>
-m
<
module name
>
-s
<
start index
>
-e
<
end index
>
Parameters
Parameter
Description
Value
devicename
Indicates the name of the
IN200 whose FEC mode is to
be queried in the system.
Example:
hinic0
and
hinic1
module name
Indicates the resource type.
all
,
glb
,
pg
,
tx
,
rx
,
yzone
,
rzone
,
nport
,
ncos
,
host
,
hsrv
,
hport
,
hpri
,
hep
, or
hque
start index
Indicates the start index of a
resource type. Each resource
type has a unique index range.
-
end index
Indicates the end index of a
resource type. Each resource
type has a unique index range,
which must be greater than or
equal to the start index.
-
Usage Instruction
None
Example
# Query the host resource information in a specified range.
[root@localhost ~]#
hinicadm pdm -i hinic0 -m host -s 0 -e 3
****** HOST RESOURCE ******
tbl_idx nm_th mqm_th gap_th nm_cnt
host0 10292 10036 150 0
host1 10292 10036 150 0
host2 10292 10036 150 0
host3 10292 10036 150 0
6.1.4.36 Querying the Interrupt Information Reported by a Hardware Module
(fm_show)
Function
The
fm_show
command is used to query the interrupt information reported by a hardware
module.
Format
hinicadm fm_show
-i
<
devicename
>
Huawei IN200 NIC
User Guide
6 Management Tools
Issue 06 (2019-07-27)
Copyright © Huawei Technologies Co., Ltd.
96