background image

No.

Description

1

Indicates the SN ID (two digits). The value is fixed to 

21

.

2

Indicates the item identification code (eight characters).

3

Indicates the vendor code (two characters). 

10

 indicates Huawei

and other values indicates manufacturing partners.

4

Indicates the year and month (two characters).

l

The first character indicates the year. The digits 1 to 9
indicate 2001 to 2009, the letters A to H indicate 2010 to
2017, the letters J to N indicate 2018 to 2022, and the letters
P to Y indicate 2023 to 2032.

NOTE

The years from 2010 are represented by upper-case letters excluding
I, O, and Z because the three letters are similar to the digits 1, 0, and
2.

l

The second character indicates the month. The digits 1 to 9
indicate January to September, and the letters A to C indicate
October to December.

5

Indicates the sequence number (six digits).

6

Indicates RoHS compliance (one character). 

Y

 indicates

compliance.

7

Indicates the internal model of the board.

 

2.3 Ports

Table 2-1

 Port description

Port

Type

Quantit
y

Description

USB port

USB 3.0
Type A

2

The panel provides two USB 3.0 ports, which
are compatible with USB 2.0.

VGA port

DB15

1

The panel provides a DB15 VGA port for local
maintenance of the compute node.

 

2.4 Indicators and Buttons

This section describes the indicators and buttons of the G530 V2.

Huawei G5500 Server G530 V2 Compute Node
White Paper

2 About the G530 V2 and GP316

Issue 03 (2018-02-12)

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

7

Содержание G530 V2

Страница 1: ...Huawei G5500 Server G530 V2 Compute Node 1 0 0 White Paper Issue 03 Date 2018 02 12 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ... be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ens...

Страница 3: ...s and Buttons 7 2 5 Physical Structure 9 2 6 Logical Structure 19 2 7 Technical Specifications 21 3 Product Features 23 4 Components 24 5 Management 30 6 Warranty 32 Huawei G5500 Server G530 V2 Compute Node White Paper Contents Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd ii ...

Страница 4: ... document is intended for l Huawei presales engineers l Channel partner presales engineers l Enterprise presales engineers Change History Changes between document issues are cumulative The latest document issue contains all changes made in previous issues Issue 03 2018 02 12 This is the third official release Mode Change Description Modify Changed ESN to SN and modified the description of the year...

Страница 5: ...te Deleted the CPU list To obtain CPU models use the Huawei Server Compatibility Checker Issue 01 2017 10 20 This issue is the first official release Huawei G5500 Server G530 V2 Compute Node White Paper 1 About This Document Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 ...

Страница 6: ...lots for installing general purpose GPU GPGPU cards and is used together with the G530 V2 to expand the computing capabilities The G530 V2 and GP316 are installed in a G5500 chassis chassis for short and centrally managed by the management module Each chassis can be installed with a maximum of two compute nodes and each compute node contains a G530 V2 and a GP316 2 2 Appearance Appearances of the ...

Страница 7: ...G530 V2 1 and G530 V2 2 The GP316 heterogeneous compute modules used together with the G530 V2 compute modules are installed in the upper two slots of the chassis corresponding to GP316 1 and GP316 2 See Figure 2 3 Huawei G5500 Server G530 V2 Compute Node White Paper 2 About the G530 V2 and GP316 Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 ...

Страница 8: ...d in the following sequence Install the GP316 and then the G530 V2 Remove the G530 V2 and then the GP316 l Maintaining one combination does not affect the proper operation of the other combination Front Panel Figure 2 4 shows the front panel of the G530 V2 Figure 2 4 Front panel of the G530 V2 1 Label plate 2 USB 3 0 ports 3 Power button indicator 4 UID button indicator 5 HLY indicator 6 Release b...

Страница 9: ... the ejector release button and ejector lever on the GP316 front panel are invisible because they are blocked by the G530 V2 After the G530 V2 is removed they can be seen SN A serial number SN is a string that uniquely identifies a server A SN is required when you apply for Huawei technical support Figure 2 6 shows the SN format Figure 2 6 SN example Huawei G5500 Server G530 V2 Compute Node White ...

Страница 10: ... 1 0 and 2 l The second character indicates the month The digits 1 to 9 indicate January to September and the letters A to C indicate October to December 5 Indicates the sequence number six digits 6 Indicates RoHS compliance one character Y indicates compliance 7 Indicates the internal model of the board 2 3 Ports Table 2 1 Port description Port Type Quantit y Description USB port USB 3 0 Type A 2...

Страница 11: ...the compute node l When the compute node is ready to be powered on you can press this button for less than 1 second to start it UID UID button indicator Blue The UID indicator is used to locate the compute node in a chassis You can remotely control the UID indicator status off on or blinking by using the management module l Off The compute node is powered off or not being located l On The compute ...

Страница 12: ...module fault indicator Yellow l Off The hard disk is operating properly l Blinking yellow The hard disk is being located or RAID is being rebuilt l Steady yellow The hard disk is faulty or not detected NVMe SSD activity indicator Green l Off The hard disk is faulty or not detected l Blinking green Data is being read from or written to the hard disk or synchronized between hard disks l Steady green...

Страница 13: ...ional 4 VGA adapter 5 Supercapacitor optional 6 Heat sink 7 M 2 adapter optional 8 M 2 FRUs optional 9 Hard disk 10 Mainboard 11 Hard disk tray 12 CPUs 13 Mezzanine card 14 BIOS battery 15 DIMMs Huawei G5500 Server G530 V2 Compute Node White Paper 2 About the G530 V2 and GP316 Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 10 ...

Страница 14: ... facilitate the capacity expansion of the RAID controller card The supercapacitor is not used in this version 6 Heat sink Cools processors The two processors of the G530 V2 use a conjoined heat sink which can meet cooling requirements for CPUs of up to 165 W thermal design power TDP The heat sink with low fin density corresponds to CPU 1 and the heat sink with high fin density corresponds to CPU 2...

Страница 15: ...th up to 165 W TDP and a maximum of 28 cores l Each processor integrates memory controllers for supporting six DDR4 memory channels Each memory channel supports two DDR4 DIMMs of 2400 or 2666 MT s l Each processor integrates PCIe controllers for supporting PCIe 3 0 and providing 48 lanes l The two processors are interconnected through two UltraPath Interconnect UPI links at 10 4 GT s l The maximum...

Страница 16: ...g and correcting ECC memory mirroring and memory sparing l Registered DIMMs RDIMMs and load reduced DIMMs LRDIMMs are supported Figure 2 8 GP316 components 1 Riser card trays 2 PCIe board 3 PCIe switches 4 Half height half length single slot cards 5 Riser cards Huawei G5500 Server G530 V2 Compute Node White Paper 2 About the G530 V2 and GP316 Issue 03 2018 02 12 Huawei Proprietary and Confidential...

Страница 17: ...A riser card houses half height half length single slot PCIe cards by providing four PCIe 3 0 x16 connectors Each connector provides x8 bandwidth PCIe Slots Table 2 5 and Table 2 6 describe the relationships between the PCIe slots and the CPUs of the G530 V2 and GP316 PCIe standards and Bus Device Function Number B D F information Table 2 5 G530 V2 PCIe device description PCIe Device CPU PCIe Stan...

Страница 18: ... 2 PCIe 3 0 x16 x8 Port 2A ae 00 0 b2 00 0 Half height half length single slot Riser 1 slot 2 CPU 2 PCIe 3 0 x16 x8 Port 2A ae 00 0 b1 00 0 Half height half length single slot Riser 1 slot 3 CPU 2 PCIe 3 0 x16 x8 Port 2A ae 00 0 b4 00 0 Half height half length single slot Riser 1 slot 4 CPU 2 PCIe 3 0 x16 x8 Port 2A ae 00 0 b3 00 0 Half height half length single slot Riser 2 slot 1 CPU 2 PCIe 3 0 ...

Страница 19: ... 3 0 x16 x8 Port 2A 3a 00 0 3e 00 0 Half height half length single slot Riser 3 slot 2 CPU 1 PCIe 3 0 x16 x8 Port 2A 3a 00 0 3d 00 0 Half height half length single slot Riser 3 slot 3 CPU 1 PCIe 3 0 x16 x8 Port 2A 3a 00 0 40 00 0 Half height half length single slot Riser 3 slot 4 CPU 1 PCIe 3 0 x16 x8 Port 2A 3a 00 0 3f 00 0 Half height half length single slot Riser 4 slot 1 CPU 1 PCIe 3 0 x16 x8 ...

Страница 20: ...f length single slot I O slots 2 and 4 CPU 2 PCIe 3 0 x16 x16 Port 2A ae 00 0 b5 00 0 b5 00 1 Half height half length single slot NOTE l The expansion slot and riser 3 slot 1 cannot be enabled at the same time Only one of the two slots can be enabled by software programming By default the expansion slot is disabled l The preceding B D F information is the system default configuration If PCIe cards...

Страница 21: ...e sleeve 8 Backplane signal connector 9 Mezzanine card tray 10 Backplane power connector 11 Virtual RAID on CPU VROC key connector 12 Hard disk backplane connector 13 Hard disk tray 14 HLY indicator 15 UID button indicator 16 Power button indicator 17 USB 3 0 ports Huawei G5500 Server G530 V2 Compute Node White Paper 2 About the G530 V2 and GP316 Issue 03 2018 02 12 Huawei Proprietary and Confiden...

Страница 22: ...he mezzanine card each PCIe switch supports two riser cards and one x16 I O slot and each riser card supports four x8 x16 slot and x8 bandwidth half height half length single slot PCIe cards The G530 V2 supports the following storage capabilities l Supports two 2 5 inch NVMe SSDs without configuring a RAID controller card The bandwidth of each SSD is PCIe 3 0 x4 Intel VROC is supported l Configure...

Страница 23: ... can be enabled by software programming By default the expansion slot is disabled Figure 2 11 Logical structure of the G530 V2 and GP316 NOTE G530 V2 1 GP316 1 MM 1 I O slot 1 and I O slot 2 are the configuration combination on the left of the chassis G530 V2 2 GP316 2 MM 2 I O slot 3 and I O slot 4 are the configuration combination on the right of the chassis The logical structures of the two con...

Страница 24: ...te 20 C h 36 F h Humidity l Operating humidity 8 to 90 RH non condensing l Storage humidity 5 to 95 RH non condensing l Humidity change rate 20 RH h Altitude l 3048 m 9999 88 ft For altitudes above 900 m 2952 72 ft the operating temperature decreases by 1 C 1 8 F every 300 m 984 24 ft l HDDs are not supported when the altitude is higher than 3000 m 9842 4 ft Corrosive gaseous contamina nt l Copper...

Страница 25: ...e equipment room l The equipment room is free from explosive conductive magnetic conductive and corrosive dust Input power specificati ons Rated input voltage 12 V DC Power consumpti on Maximum power consumpti on l G530 V2 600 W l GP316 1400 W Huawei G5500 Server G530 V2 Compute Node White Paper 2 About the G530 V2 and GP316 Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei ...

Страница 26: ...s the G530 V2 delivers higher processing performance l The GP316 supports 16 NVIDIA P4 cards increasing the computing capabilities for the G530 V2 l The G530 V2 provides multiple flexible hard disk configuration solutions Two 2 5 inch NVMe SSDs Two 2 5 inch SAS SATA hard disks supporting RAID 0 or 1 l The GP316 PCIe slots PCIe switches and system I O modules can be powered on synchronously with th...

Страница 27: ...cessor integrates PCIe controllers for supporting PCIe 3 0 and providing 48 lanes l The two processors are interconnected through two UltraPath Interconnect UPI links at 10 4 GT s l The maximum frequency is 3 6 GHz Memory The G530 V2 provides 24 slots for installing DIMMs 12 DIMMs for each processor At least one DIMM must be configured Memory Configuration Rules Observe the following rules when co...

Страница 28: ...peed MT s 2666 2666 Rated voltage V 1 2 1 2 Operating voltage V 1 2 1 2 Maximum number of DIMMs 24 24 Maximum capacity per DIMM GB 32 64 Maximum memory capacity GB 768 1536 Maximum memory capacity at maximum operating speed GB 768 1536 Maximum operating speed MT s One DIMM per channel 2666 2666 Two DIMMs per channel 2666 2666 This table is for reference only For details about the components that c...

Страница 29: ...U 2 2A DIMM100 2A1 DIMM101 2A2 2B DIMM110 2B1 DIMM111 2B2 2C DIMM120 2C1 DIMM121 2C2 2D DIMM130 2D1 DIMM131 2D2 2E DIMM140 2E1 DIMM141 2E2 2F DIMM150 2F1 DIMM151 2F2 Table 4 3 shows the DIMM installation rules See Figure 2 9 for DIMM slot numbers Huawei G5500 Server G530 V2 Compute Node White Paper 4 Components Issue 03 2018 02 12 Huawei Proprietary and Confidential Copyright Huawei Technologies C...

Страница 30: ...1D1 1E1 1F1 2A1 2B1 2C1 2D1 2E1 2F1 13 Unbalanc ed 1A1 1A2 1B1 1C1 1D1 1E1 1F1 2A1 2B1 2C1 2D1 2E1 2F1 14 Unbalanc ed 1A1 1A2 1B1 1C1 1D1 1E1 1F1 2A1 2A2 2B1 2C1 2D1 2E1 2F1 15 Unbalanc ed 1A1 1A2 1B1 1B2 1D1 1D2 1E1 1E2 2A1 2A2 2B1 2C1 2D1 2E1 2F1 16 Balanced 1A1 1A2 1B1 1B2 1D1 1D2 1E1 1E2 2A1 2A2 2B1 2B2 2D1 2D2 2E1 2E2 17 Unbalanc ed 1A1 1A2 1B1 1B2 1C1 1C2 1D1 1E1 1F1 2A1 2A2 2B1 2B2 2D1 2D2 ...

Страница 31: ...PU cards supported by the GP316 Model Vendor Specifications Auxiliary Power Connector Type Installation Position P4 NVIDIA PCIe 3 0 x16 8 GB 75 W None Riser 1 slots 1 to 4 Riser 2 slots 1 to 4 Riser 3 slots 1 to 4 Riser 4 slots 1 to 4 Hard Disk The G530 V2 can be configured with up to two 2 5 inch HDDs or SSDs Each hard disk can be independently installed and removed and is hot swappable The G530 ...

Страница 32: ...one I O module that supports a maximum of two half height half length single slot PCIe 3 0 x16 cards l One LAN On Motherboard LOM NIC that provides two SFP Ethernet ports through the management module PSU The G530 V2 and GP316 are powered by PSUs in the G5500 chassis and do not require independent power supply Peripheral The G530 V2 supports peripherals such as a USB DVD ROM drive OS and Software ...

Страница 33: ...ibes the features of the iBMC Table 5 1 iBMC features Feature Description Management interface Integrates with any standard management system through the following interfaces l IPMI V2 0 l CLI l HTTPS Fault detection Detects faults and accurately locates hardware faults System watchdog Supports BIOS power on self test POST OS watchdog and automatic system reset for timeout You can enable or disabl...

Страница 34: ...4 l Google Chrome 21 43 l Safari 5 1 Fault reproduction Reproduces faults to facilitate fault diagnosis Screen snapshots and screen videos Allows you to view screenshots and videos without login which facilitates routine preventive maintenance inspection PMI DNS LDAP Supports the DNS and AD significantly simplifying network and configuration management Dual image backup Starts software from a back...

Страница 35: ...nditions including the available services response time terms of service and disclaimer The warranty terms and conditions may vary by country and some services and or parts may not be available in all countries For more information about warranty services in your country contact Huawei technical support or the local Huawei representative office Huawei G5500 Server G530 V2 Compute Node White Paper ...