Replacing a 2.5-inch Drive
Installing a Drive
1. Determine the location for installing the drive.
2. Take a spare drive out of its ESD bag.
3. Completely raise the ejector lever and insert the drive into the
slot. See (1) in the figure.
4. Lower the ejector lever until it is latched. See (2) in the figure.
5. Configure the drive based on the actual situation. The
following is only for reference:
If the original drive is not in the RAID array, the new drive
becomes idle. You are advised to set the new drive as a global
or dedicated hot spare disk. The procedure ends.
If the original RAID array (for example, RAID 0) does not
support redundancy, reconfigure RAID. The procedure ends.
If the original RAID array is redundant and has a hot spare disk,
the new drive becomes idle. You are advised to set the new
drive as a global or dedicated hot spare disk. The procedure
ends.
If the original RAID array is redundant but does not have a hot
spare disk, data is automatically rebuilt to the new drive. The
procedure ends.
For details, see
Содержание FusionServer Pro G5500
Страница 21: ...Page 21 Copyright Huawei Technologies Co Ltd 2020 1 2 Routine Inspection Remote Inspection Inspection result ...
Страница 40: ...Page 40 Copyright Huawei Technologies Co Ltd 2020 FusionServer Tools Toolkit ...
Страница 91: ...Page 91 Copyright Huawei Technologies Co Ltd 2020 Questions 1 How to install the power cable for the GPU card ...
Страница 93: ...www huawei com Thank you ...