Table 5-6 M.2 FRU indicator description
Indicator
Description
M.2 FRU fault
indicator
● Off: The M.2 FRU is running properly.
● Blinking yellow: The M.2 FRU is being located, or
RAID is being rebuilt.
● Steady yellow: The M.2 FRU is faulty or not
detected.
M.2 FRU activity
indicator
● Off: The M.2 FRU is not in position or is faulty.
● Blinking green: Data is being read, written, or
synchronized.
● Steady green: The M.2 FRU is inactive.
NVMe Drive Indicators
Figure 5-14 NVMe drive indicators
Table 5-7 Description of NVMe drive indicators (only orderly hot swap supported)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive cannot be detected.
Steady on
Off
The NVMe drive is working properly.
Blinking at 2 Hz
Off
Data is being read from or written to
the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The hot removal process is complete,
and the NVMe drive is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.