background image

Country/Region

Certification

Standards

China

RoHS

SJ/T-11364
GB/T 26572

Australia

RCM

AS/NZS CISPR32: 2015
EN 55032:2012/AC:2013
EN 55032:2015/AC:2016

America

FCC

FCC Part 15 (Class A)

America

NRTL

UL 62368-1:2014 Ed.2
CSA
C22.2#62368-1:2014 Ed.2]
UL 60950-1:2007 Ed.2
+R:14Oct2014]
CSA C22.2#60950-
1:2007 Ed.2 +A1;A2]

Canada

IC

ICES-003 Class A

Canada

NRTL

UL 62368-1:2014 Ed.2
CSA
C22.2#62368-1:2014 Ed.2]
UL 60950-1:2007 Ed.2
+R:14Oct2014]
CSA C22.2#60950-
1:2007 Ed.2 +A1;A2]

Nigeria

SONCAP

IEC 60950-1: 2005 (2nd Edition) +

A1:2009
EN 60950-1:2006+A11:2009+A1:2010 +

A12:2011

Kingdom of Saudi

Arabia (KSA)

SASO

IEC 60950-1: 2005 (2nd Edition) +

A1:2009
EN 60950-1:2006+A11:2009+A1:2010 +

A12:2011

Global

CB

IEC 60950-1

Japan

VCCI

VCCI 32-1

Saudi, Nigeria,

Tanzania, Uganda,

Kuwait, Algeria,

Botswana, Qatar,

Egypt

Multi-

country_certificate

IEC 60950-1: 2005 (2nd Edition) +

A1:2009
EN 60950-1:2006+A11:2009+A1:2010 +

A12:2011

Huawei FusionServer Pro 2488H V6 Server

Technical White Paper

10 Certifications

Issue 03 (2021-02-01)

Copyright © Huawei Technologies Co., Ltd.

87

Содержание FusionServer Pro 2488H V6

Страница 1: ...Huawei FusionServer Pro 2488H V6 Server Technical White Paper Issue 03 Date 2021 02 01 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Страница 3: ...evel of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss perfo...

Страница 4: ...ronment deterioration Change History Issue Date Description 03 2021 02 01 This issue is the third official release 02 2020 12 09 This issue is the second official release 01 2020 10 21 This issue is the first official release Huawei FusionServer Pro 2488H V6 Server Technical White Paper About This Document Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd iii ...

Страница 5: ...4 1 2 Memory Subsystem Architecture 24 5 4 1 3 Memory Compatibility 26 5 4 1 4 Memory Installation Guidelines 28 5 4 1 5 Memory Installation Positions 28 5 4 1 6 Memory Protection Technologies 30 5 4 2 PMem 31 5 4 2 1 Memory Identifier 31 5 4 2 2 Memory Subsystem Architecture 31 5 4 2 3 Memory Compatibility 33 5 4 2 4 Memory Installation Guidelines 34 5 4 2 5 Memory Installation Positions 35 5 4 2...

Страница 6: ...s 71 6 1 Technical Specifications 71 6 2 Environmental Specifications 75 6 3 Physical Specifications 77 7 Software and Hardware Compatibility 79 8 Safety Instructions 80 8 1 Safety Instructions 80 8 2 Maintenance and Warranty 83 9 System Management 84 10 Certifications 86 A Appendix 88 A 1 Product SN 88 A 2 Operating Temperature Limitations 89 A 3 Nameplate 92 A 4 RAS Features 92 A 5 Sensor List 9...

Страница 7: ...and Abbreviations 102 C 1 A E 102 C 2 F J 103 C 3 K O 104 C 4 P T 105 C 5 U Z 107 Huawei FusionServer Pro 2488H V6 Server Technical White Paper Contents Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd vi ...

Страница 8: ... and deep learning The secure compact 2488H V6 is a highly expandable server delivering high performance computing large storage capacity and low power consumption It is easy to deploy and manage and supports virtualization NOTE For details about the 2488H V6 nameplate information see A 3 Nameplate Figure 1 1 Physical structure of a 2488H V6 with 8 x 2 5 drives example Huawei FusionServer Pro 2488...

Страница 9: ... each processor core to run up to two threads improving parallel computation capability The hardware assisted Intel Virtualization Technology Intel VT allows operating system OS to better use hardware to address virtualization workloads Intel Deep Learning Boost Intel DL Boost works with the latest bfloat16 instruction set and Vector Neural Network Instructions VNNI to accelerate AI training and i...

Страница 10: ...r with flexible configuration of GE 10GE 25GE 100GE network adapters which are hot swappable and support network controller sideband interface NC SI HTTPS boot preboot execution environment PXE and Wake on LAN WoL Availability and Serviceability Carrier class components with process expertise ensure high system reliability and availability The server supports hot swappable SAS SATA NVMe drives SAS...

Страница 11: ...tem security The following requirements in NIST SP 800 147B are met The BIOS firmware digital signature update mechanism is supported During the upgrade the digital signature is verified to prevent unauthorized BIOS firmware upgrade The flash security protection mechanism is supported to prevent unauthorized modification of the flash memory in the OS NOTE The service port with NC SI enabled suppor...

Страница 12: ...owered on or off based on requirements The low voltage third generation Intel Xeon Scalable Cooper Lake processors consume less energy ideally suited for data centers and telecommunications environments constrained by power and thermal limitations SSDs consume 80 less power than HDDs Huawei FusionServer Pro 2488H V6 Server Technical White Paper 2 Features Issue 03 2021 02 01 Copyright Huawei Techn...

Страница 13: ...e of a 2488H V6 with 8 x 2 5 drives example 1 PCIe riser module 1 2 PCIe cards 3 PCIe riser module 2 4 PSUs Huawei FusionServer Pro 2488H V6 Server Technical White Paper 3 Physical Structure Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 6 ...

Страница 14: ...ed with a supercapacitor For details about the slots for installing PCIe RAID controller cards see 5 5 1 Drive Configurations b Secondary air ducts are not required when full length PCIe cards are configured c If an M 2 SSD adapter card is configured two M 2 SSDs can be configured in slot 10 If an Avago SAS3004iMR RAID controller card is configured two M 2 FRUs can be configured in slot 1 For deta...

Страница 15: ...a maximum of 11 PCIe 3 0 expansion slots including one slot dedicated for the OCP 3 0 network adapter The LBG R Platform Controller Hub PCH is integrated on the mainboard to support five USB 3 0 ports and two SATA 3 0 ports The Hi1711 management chip integrated on the mainboard supports a video graphic array VGA port a management network port and a serial port Huawei FusionServer Pro 2488H V6 Serv...

Страница 16: ...O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 LCD 5 11 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 1 Front view Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 9 ...

Страница 17: ...ate with an SN label 20 x 2 5 drive pass through configuration 4 x SAS SATA 16 x NVMe Figure 5 3 Front view 1 SAS SATA drives 2 NVMe drives 3 Filler panel in drive slot NOTE The slot cannot hold drives 4 Slide out label plate with an SN label 24 x 2 5 drive pass through configuration 24 x SAS SATA Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02...

Страница 18: ... 25 x SAS SATA Figure 5 5 Front view 1 SAS SATA drives 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons 8 x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 6 Indicators and buttons on the front panel Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 11 ...

Страница 19: ...dicator 5 FlexIO card presence indicator 6 iBMC direct connect management port indicator 20 x 2 5 drive pass through configuration 4 x SAS SATA 16 x NVMe Figure 5 8 Indicators and buttons on the front panel 1 Fault diagnosis LED 2 Power button indicator 3 Health status indicator 4 UID button indicator 5 FlexIO card presence indicator 6 iBMC direct connect management port indicator 24 x 2 5 drive p...

Страница 20: ...cator 3 Health status indicator 4 UID button indicator 5 FlexIO card presence indicator 6 iBMC direct connect management port indicator Indicator and Button Description Table 5 1 Indicators and buttons on the front panel Silkscreen Indicator Button Description Fault diagnosis LED The device is operating properly Error code A component is faulty For details about error codes see FusionServer Pro Ra...

Страница 21: ...llow you can press this button to power on the device Health status indicator Off The device is powered off or is faulty Blinking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly UID button indicator The UID button indicator helps identify and locate a device UID indicator...

Страница 22: ...agement port connects to a terminal local PC or Android mobile phone Off No terminal is connected Blinking green at short intervals for 3 seconds and then off The port is disabled Steady green The terminal is connected 5 1 3 Ports 8 x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 11 Ports on the front panel 1 USB 3 0 ports 2 iBMC direct connect management port 3 VGA port 12 x 2 5 driv...

Страница 23: ...agement port 3 VGA port 24 x 2 5 drive pass through configuration 24 x SAS SATA Figure 5 14 Ports on the front panel 1 USB 3 0 ports 2 iBMC direct connect management port 3 VGA port 25 x 2 5 drive EXP configuration 25 x SAS SATA Figure 5 15 Ports on the front panel Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies...

Страница 24: ...are supported To log in to the iBMC from the local PC enter https IP address of the iBMC management network port in the address box of the browser on the local PC When accessing the iBMC through a mobile phone you need to use the mobile application SmartServer to access the iBMC For details see Huawei Server SmartServer Mobile User Guide USB 3 0 port USB 3 0 2 Used to connect to a USB device NOTIC...

Страница 25: ...d NOTE The FlexIO card slot supports only OCP 3 0 network adapters NOTE For details about the OCP 3 0 network adapter see 5 6 1 OCP 3 0 Network Adapter The figure is for reference only The actual configuration may vary 5 2 2 Indicators and Buttons Indicator Positions Figure 5 17 Indicators on the rear panel Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue ...

Страница 26: ...ds support only orderly hot swap For details see Table 5 4 Data transmission status indicator for the management network port Off No data is being transmitted Blinking yellow Data is being transmitted Connection status indicator for the management network port Off The network port is not connected Steady green The network port is connected properly Health status indicator Off The device is powered...

Страница 27: ...utput are normal Steady orange The input is normal but there is no output NOTE The possible causes of no power output are as follows Power supply overtemperature protection Power output overcurrent or short circuit Output overvoltage Short circuit protection Device failure excluding failure of all devices Table 5 4 FlexIO card power indicator and status indicator FlexIO Card Power Indicator Green ...

Страница 28: ...2 Serial port 3 VGA port 4 USB 3 0 ports 5 Socket for PSU 1 6 Socket for PSU 2 Port Description Table 5 5 Ports on the rear panel Port Type Quantity Description Management network port RJ45 1 iBMC management network port which is used to manage the server NOTE The management network port is a GE port that supports 100 Mbit s and 1000 Mbit s auto negotiation Huawei FusionServer Pro 2488H V6 Server ...

Страница 29: ...to a power distribution unit PDU through a power cable You can select the PSUs as required NOTE When determining the PSUs ensure that the rated power of the PSUs is greater than that of the server If only one PSU is used Work Mode cannot be set to Active Standby on the Power page of the iBMC WebUI 5 3 Processor The server supports two or four processors If two processors are required install them ...

Страница 30: ...entifier You can determine the memory module properties based on the label attached to the memory module Figure 5 20 Memory identifier Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 23 ...

Страница 31: ...itecture The 2488H V6 provides 48 memory slots Each processor integrates six memory channels Install the memory modules in the primary memory channels first If the primary memory channel is not populated the memory modules in secondary memory channels cannot be used Table 5 6 Memory channels CPU Memory Channel Memory Slot CPU 1 A primary DIMM000 A A DIMM001 G B primary DIMM010 B B DIMM011 H C prim...

Страница 32: ...31 J E primary DIMM140 E E DIMM141 K F primary DIMM150 F F DIMM151 L CPU 3 A primary DIMM200 A A DIMM201 G B primary DIMM210 B B DIMM211 H C primary DIMM220 C C DIMM221 I D primary DIMM230 D D DIMM231 J E primary DIMM240 E E DIMM241 K F primary DIMM250 F F DIMM251 L CPU 4 A primary DIMM300 A Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Co...

Страница 33: ...memory modules of different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together Contact your local Huawei sales representative or see Search Parts in the Computing Product Compatibility Checker to determine the components to be used The memory can be used with the third generation Intel Xeon Scalable Cooper Lake processors The maximum memory capacit...

Страница 34: ...y per DDR4 memory module GB 16 32 64 128 Type RDIMM RDIMM RDIMM LRDIMM Rated speed MT s 3200 3200 3200 3200 Operating voltage V 1 2 1 2 1 2 1 2 Maximum number of DDR4 memory modules in a servera 48 48 48 48 Maximum DDR4 memory capacity of the server GB b 768 1536 3072 6144 Actual rate MT s 1 DPCc 3200 3200 3200 3200 2 DPC 3200 3200 3200 3200 a The maximum number of DDR4 DIMMs is based on four proc...

Страница 35: ...o channels channels 1 and 2 or channels 1 2 and 3 for installing DIMMs The installed DIMMs must be identical in size and organization For a multi processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with the general installation guidelines 5 4 1 5 Memory Installation Positions A 2488H V6 supports a maximum of 48 DDR4 DIMMs To maximize...

Страница 36: ...Figure 5 21 Memory slots Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 29 ...

Страница 37: ...nologies are supported ECC Memory Mirroring Memory Single Device Data Correction SDDC 1 Failed DIMM Isolation Memory Thermal Throttling Command Address Parity Check and Retry Memory Demand Patrol Scrubbing Memory Data Scrambling Memory Multi Rank Sparing Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 30 ...

Страница 38: ... Intel OptaneTM Persistent Memory 2 SN 8089 A2 2008 00002461 3 Model NMB1XXD512GPSU4 4 Capacity GB 128 256 512 5 SN QR code 8089 A2 2008 00002461 5 4 2 2 Memory Subsystem Architecture The 2488H V6 provides 48 memory slots Each processor integrates six memory channels and each memory channel supports only one PMem module Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Descr...

Страница 39: ... DIMM021 I D primary DIMM030 D D DIMM031 J E primary DIMM040 E E DIMM041 K F primary DIMM050 F F DIMM051 L CPU 2 A primary DIMM100 A A DIMM101 G B primary DIMM110 B B DIMM111 H C primary DIMM120 C C DIMM121 I D primary DIMM130 D D DIMM131 J E primary DIMM140 E E DIMM141 K F primary DIMM150 F F DIMM151 L CPU 3 A primary DIMM200 A A DIMM201 G B primary DIMM210 B Huawei FusionServer Pro 2488H V6 Serv...

Страница 40: ... F primary DIMM350 F F DIMM351 L 5 4 2 3 Memory Compatibility Observe the following rules when configuring PMem modules NOTICE The DCPMMs must be used with the DDR4 memory modules For details see Huawei FusionServer Pro PMem 200 User Guide Contact your local Huawei sales representative or see Search Parts in the Computing Product Compatibility Checker to determine the components to be used Huawei ...

Страница 41: ...pecifications Capacity per PMem module GB 128 256 512 Rated speed MT s 3200 3200 3200 Operating voltage V 1 2 1 2 1 2 Maximum number of PMem modules in a servera 24 24 24 Maximum PMem capacity of the server GB b 3072 6144 12288 Actual rate MT s 2666 2666 2666 a The maximum number of PMem modules is based on four processor configuration The value is halved for a server with two processors b The max...

Страница 42: ...ory capacity supported by a CPU CPU Type Maximum Memory Capacity Supported by a CPU DDR4 and PMem Capacities Cooper Lake H series 1 12 TB 6 x 64 GB DDR4 6 x 128 GB PMem Cooper Lake HL series 4 5 TB 6 x 256 GB DDR4 6 x 512 GB PMem Note For details about the configurable memory capacity see Search Parts in the Computing Product Compatibility Checker 5 4 2 5 Memory Installation Positions A 2488H V6 s...

Страница 43: ...Figure 5 25 Memory slots Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 36 ...

Страница 44: ...Figure 5 26 PMem installation guidelines 2 processor Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 37 ...

Страница 45: ...rror Detection and Correction PMem module Device Failure Recovery SDDC PMem module Package Sparing DDDC PMem module Patrol Scrubbing PMem module Address Error Detection PMem module Data Poisoning Corrupt Data Containment Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 38 ...

Страница 46: ...d and Address Parity Check and Retry DDR T Read Write Data ECC Check and Retry PMem module Faulty DIMM Isolation PMem module Error Reporting 5 5 Storage Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 39 ...

Страница 47: ...rts M 2 SSDs 2 x M 2 SSDs The M 2 SSD adapter card in slot 10 supports M 2 SSDs SAS SATA drive 1 x PCIe RAID controll er card The PCIe RAID controll er card in slot 4 manage s the SAS SATA drives in slots 0 to 7 M 2 SSD PCH Manage s the M 2 SSDs on the M 2 SSD adapter card in slot 10 Intel VROC SATA RAID Manage s the M 2 SSDs on the M 2 SSD adapter card in slot 10 Huawei FusionServer Pro 2488H V6 ...

Страница 48: ...ent Mode 1 x PCIe RAID controll er card Manage s the M 2 SSDs on the Avago SAS300 4iMR PCIe RAID controll er card in slot 1 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 41 ...

Страница 49: ...n slot 1 supports M 2 SSDs N A SAS SATA drive 1 x PCIe RAID controll er card The PCIe RAID controll er card in slot 4 manage s the SAS SATA drives in slots 0 to 3 NVMe drive CPU Manage s the NVMe drives in slots 4 to 11 M 2 SSD 1 x PCIe RAID controll er card Manage s the M 2 SSDs on the Avago SAS300 4iMR PCIe RAID controll er card in slot 1 Huawei FusionServer Pro 2488H V6 Server Technical White P...

Страница 50: ...ler card in slot 1 supports M 2 SSDs N A SAS SATA drive 1 x PCIe RAID controll er card The PCIe RAID controll er card in slot 4 manage s the SAS SATA drives in slots 0 to 3 NVMe drive CPU Manage s the NVMe drives in slots 4 to 11 and slots 16 to 23 M 2 SSD 1 x PCIe RAID controll er card Manage s the M 2 SSDs on the Avago SAS300 4iMR PCIe RAID controll Huawei FusionServer Pro 2488H V6 Server Techni...

Страница 51: ...nt Drive Rear Drive Built in Drive Drive Management Mode er card in slot 1 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 44 ...

Страница 52: ...s M 2 SSDs 2 x M 2 SSDs The M 2 SSD adapter card in slot 10 supports M 2 SSDs SAS SATA drive 3 x PCIe RAID controll er cards The PCIe RAID contr oller card in slot 2 man ages the drive s in slots 8 to 15 The PCIe RAID contr oller card in slot 4 man ages the drive s in slots 0 to 7 The PCIe RAID contr oller card Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Is...

Страница 53: ...Ds on the M 2 SSD adapter card in slot 10 Intel VROC SATA RAID Manage s the M 2 SSDs on the M 2 SSD adapter card in slot 10 1 x PCIe RAID controll er card Manage s the M 2 SSDs on the Avago SAS300 4iMR PCIe RAID Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 46 ...

Страница 54: ...rive Rear Drive Built in Drive Drive Management Mode controll er card in slot 1 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 47 ...

Страница 55: ...rd in slot 10 supports M 2 SSDs SAS SATA drive 1 x PCIe RAID controll er card The PCIe RAID controll er card in slot 4 manage s the SAS SATA drives in slots 0 to 24 M 2 SSD PCH Manage s the M 2 SSDs on the M 2 SSD adapter card in slot 10 Intel VROC SATA RAID Manage s the M 2 SSDs on the M 2 SSD adapter card in slot 10 1 x PCIe RAID controll er card Huawei FusionServer Pro 2488H V6 Server Technical...

Страница 56: ...ing on the cabling of the RAID controller card The drive numbers identified by the RAID controller card in this section are provided based on the default cabling described in Internal Cabling in FusionServer Pro 2488H V6 Maintenance and Service Guide 8 x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 28 Drive numbering Table 5 12 Drive numbering Drive Number Drive Number Displayed on t...

Страница 57: ...n 4 x SAS SATA 8 x NVMe Figure 5 29 Drive numbering Table 5 13 Drive numbering Drive Number Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 50 ...

Страница 58: ...C WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 x 2 5 drive pass through configuration 24 x SAS SATA Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 51 ...

Страница 59: ...y the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 0 9 9 1 10 10 2 11 11 3 12 12 4 13 13 5 14 14 6 15 15 7 16 16 0 17 17 1 18 18 2 19 19 3 20 20 4 21 21 5 22 22 6 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 52 ...

Страница 60: ...6 Drive numbering Drive Number Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 13 13 13 14 14 14 15 15 15 16 16 16 17 17 17 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 53...

Страница 61: ...tor Yellow Description Steady on Off The drive is detected Blinking at 4 Hz Off Data is being read or written properly or data on the primary drive is being rebuilt Steady on Blinking at 1 Hz The drive is being located Blinking at 1 Hz Blinking at 1 Hz Data on the secondary drive is being rebuilt Off Steady on A drive in a RAID array is removed Steady on Steady on The drive is faulty Huawei Fusion...

Страница 62: ...to the NVMe drive Off Blinking at 2 Hz The NVMe drive is being located or hot swapped Off Blinking at 0 5 Hz The NVMe drive has completed the hot swap process and is removable Steady on Off Steady on The NVMe drive is faulty M 2 FRU Indicators The server supports the Avago SAS3004iMR RAID controller card which supports two M 2 FRUs Figure 5 35 M 2 FRU indicators Huawei FusionServer Pro 2488H V6 Se...

Страница 63: ...ei sales representative or see Search Parts in the Computing Product Compatibility Checker to determine the components to be used For details about the RAID controller card see Huawei V6 Server RAID Controller Card User Guide 5 6 Network 5 6 1 OCP 3 0 Network Adapter OCP 3 0 network adapters provide network expansion capabilities The FlexIO slot supports only the OCP 3 0 network adapter which can ...

Страница 64: ... riser module 1 provides slots 1 2 and 3 If a dual slot PCIe riser module is used slot 3 is unavailable PCIe riser module 2 provides slots 7 8 and 9 If a dual slot PCIe riser module is used slot 9 is unavailable The mainboard provides slots 4 5 6 and 10 PCIe Riser Modules PCIe riser module universal 3 slot Provides PCIe slots 1 2 and 3 when installed in PCIe riser module 1 Provides PCIe slots 7 8 ...

Страница 65: ...riser module universal 2 slot PCIe riser module universal 3 slot supporting GPUs Provides PCIe slots 1 2 and 3 when installed in PCIe riser module 1 Provides PCIe slots 7 8 and 9 when installed in PCIe riser module 2 NOTE A full height full length dual width GPU occupies an adjacent slot Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyri...

Страница 66: ...hen installed in PCIe riser module 2 NOTE A full height full length dual width GPU occupies an adjacent slot Figure 5 40 PCIe riser module universal 2 slot supporting GPUs 5 7 3 PCIe Slot Description NOTE The PCIe slots mapping to a vacant CPU socket are unavailable Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologie...

Страница 67: ...ot 3 CPU 4 PCIe 3 0 x16 2 slot PCI e rise r mo dul e PR M N A 3 slot PR M x16 Port1A 0xC3 0 0 0xC4 0 0 FHHL Slot 4 CPU 1 PCIe 3 0 x8 x8 Port2C 0x23 2 0 0x25 0 0 HHHL Slot 5 CPU 2 PCIe 3 0 x8 x8 Port4A 0x6C 0 0 0x6D 0 0 HHHL Slot 6 CPU 2 PCIe 3 0 x8 x8 Port4C 0x6C 2 0 0x6E 0 0 HHHL Slot 7 CPU 2 PCIe 3 0 x16 x8 Port1A 0x43 0 0 0x44 0 0 FHFL Slot 8 CPU 2 PCIe 3 0 x16 x16 Port2A 0x57 0 0 0x58 0 0 FHFL...

Страница 68: ...and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half length FHHL PCIe slots are compatible with FHHL PCIe cards and half height half length HHHL PCIe cards The maximum power supply of each PCIe slot is 75 W 5 8 PSUs The server supports one or two PSUs The server supports AC or DC PSUs The PSUs a...

Страница 69: ...the output power decreases to 1300 W If the input voltage ranges from 200 V AC to 220 V AC the output power decreases to 2500 W If the input voltage ranges from 220 V AC to 230 V AC the output power decreases to 2900 W 5 9 Fan Modules The server supports six fan modules The fan modules are hot swappable N 1 redundancy is supported That is the server can work properly when a single fan fails The fa...

Страница 70: ...enables users to set the IP address of the iBMC management network port on the server The LCD and the server iBMC form an LCD subsystem The LCD directly obtains device information from the iBMC The LCD subsystem does not store device data Figure 5 43 LCD subsystem working principle Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Hu...

Страница 71: ...mperature of the server Info Displays the IP address and MAC address of the iBMC management network port device SNs asset information and firmware version Setting Sets the IP address of the iBMC management network port For details about how to use the LCD see FusionServer Pro Rack Server LCD User Guide x86 V6 5 11 Boards Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Desc...

Страница 72: ... CONN J14 3 Serial port IO IO J148 4 BMC management network port BMC Mesg J149 5 PCIe slot 6 PCIE SLOT CPU2 X8 J132 6 PCIe slot 5 PCIE SLOT CPU2 X8 J131 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 65 ...

Страница 73: ...nnector 6 FAN6 J12 23 Fan board connector POD7 J72 a 24 6038 fan module connector 6 FAN6 POD6 J2007 25 6076 fan module connector 5 FAN5 J11 26 6038 fan module connector 5 FAN5 POD5 J2006 27 6076 fan module connector 4 FAN4 J8 28 6038 fan module connector 4 FAN4 POD4 J2005 29 6076 fan module connector 3 FAN3 J7 30 6038 fan module connector 3 FAN3 POD3 J2004 31 6076 fan module connector 2 FAN2 J4 32...

Страница 74: ...N J10 46 Power connectors for the PSU backplane PDB POWER CONN J153 J154 J155 47 SATA connector 2 DVD drive connector SATA2 DVD J74 48 SATA connector 1 SATA1 J73 49 Intrusion sensor connector S1 50 PCIe riser 2 slot PCIE RISER2 CPU2 J88 a Reserved and unavailable currently 5 11 2 Drive Backplane Front Drive Backplane 8 x 2 5 drive pass through backplane 8 x SAS SATA Figure 5 46 8 x 2 5 drive pass ...

Страница 75: ...x NVMe 1 LP slimline 2 connector SLIM_2 J1001 2 LP slimline 1 connector SLIM_1 J901 3 LP slimline 4 connector SLIM_4 J1201 4 LP slimline 3 connector SLIM_3 J1101 5 Power connector HDD POWER J4003 6 Backplane signal cable connector HDD_BP J3702 7 mini SAS HD Port A connector PORTA J801 20 x 2 5 drive pass through backplane 4 x SAS SATA 16 x NVMe Figure 5 48 20 x 2 5 drive pass through backplane 4 x...

Страница 76: ...e backplane HDD_Power2 J7303 15 14 pin power connector for the drive backplane HDD_Power1 J30 16 Signal connector for the drive backplane HDD_BP J7102 24 x 2 5 drive pass through backplane 24 x SAS SATA Figure 5 49 24 x 2 5 drive pass through backplane 24 x SAS SATA 1 mini SAS HD Port 3B connector PORT3B J33 2 mini SAS HD Port 3A connector PORT3A J39 3 mini SAS HD Port 2B connector PORT2B J31 4 mi...

Страница 77: ...kplane HDD_BP J1 6 Power connector for the drive backplane POWER J24 7 Signal connector for the built in backplane REAR BP1 J35 a a Reserved and unavailable currently 5 11 3 PSU Backplane Figure 5 51 2488H V6 PSU backplane 1 Signal connector for the PSU backplane J306 2 Power connector J304 3 Power connector J303 4 Power connector J305 Huawei FusionServer Pro 2488H V6 Server Technical White Paper ...

Страница 78: ... memory controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Six UPI buses between processors providing up to 10 4 GT s transmission per channel Up to 28 cores per processor Max 3 9 GHz Min 1 375 MB L3 cache per core Max 250 W TDP NOTE The preceding information is for reference only For details see Search Parts in the Computing Product Compatib...

Страница 79: ...odules and the DDR4 memory module can be installed only in the memory slot of the primary memory channel The PMem module supports only the AD mode Max 2666 MT s memory speed The PMem modules of different specifications capacity and rank cannot be used together For details about the PMem modules see Huawei FusionServer Pro PMem 200 User Guide NOTE The preceding information is for reference only For...

Страница 80: ... SSD cannot be used to store data due to poor endurance In write intensive applications the M 2 SSD will wear out in a short time If you want to use SSDs or HDDs as data storage devices use enterprise level SSDs or HDDs with high DWPD The M 2 SSD is not recommended for write intensive service software due to poor endurance Do not use M 2 SSDs for cache Supports hot swap of SAS SATA NVMe drives NOT...

Страница 81: ...ils see 5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description Two full height full length dual width GPU cards NOTE The preceding information is for reference only For details see Search Parts in the Computing Product Compatibility Checker Port Supports a variety of ports Ports on the front panel Two USB 3 0 ports One USB Type C iBMC direct connect management port One DB15 VGA port Ports on the rear pa...

Страница 82: ...tems Integration with Huawei management systems eSight FusionDirector Security feature Power on password Administrator password TCM only in China TPM Secure boot Front bezel optional Chassis cover opening detection 6 2 Environmental Specifications Table 6 2 Environmental specifications Category Specifications Temperature Operating temperature 5 C to 40 C 41 F to 104 F ASHRAE Classes A1 to A3 compl...

Страница 83: ... decreases by 1 C 1 8 F for every increase of 175 m 574 14 ft HDDs cannot be used at an altitude of over 3050 m 10006 44 ft Corrosive gaseous contaminant Maximum corrosion product thickness growth rate Copper corrosion rate test 300 Å month meeting level G1 requirements of the ANSI ISA 71 04 2013 standard on gaseous corrosion Silver corrosion rate test 200 Å month Particle contaminant The equipmen...

Страница 84: ... W x D 86 1 mm x 447 mm x 790 mm 3 39 in x 17 60 in x 31 10 in Installation space Requirements for cabinet installation Cabinet compliant with the International Electrotechnical Commission IEC 297 standard Cabinet width 482 6 mm 19 00 in Cabinet depth 1000 mm 39 37 in Requirements for guide rail installation L shaped guide rails apply only to Huawei cabinets Static rail kit applies to cabinets wit...

Страница 85: ... 70 71 lb Server with 25 x 2 5 drives 32 44 kg 71 53 lb Packing material 5 kg 11 03 lb Power consumption The power consumption parameters vary with hardware configurations including the configurations complying with EU ErP Use the Computing Product Power Calculator to obtain specific information Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Issue 03 2021 02...

Страница 86: ...ic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact Huawei sales personnel to apply for POC tests in the pre sales phase to determine detailed software and hardware configurations If the customer has requirements on hardware performance consist...

Страница 87: ...ving a forklift Take protective measures against radio interference before operating the device in residential areas Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operate the product o...

Страница 88: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 2488H V6 Server Technical White Paper 8 Sa...

Страница 89: ... the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury Connect the primary and secondary power cables to different power distribution units PDUs to ensure reliable system operation Properly ground a device before powering it on Transportation Precautions Improper transportation may damage equipment Contact th...

Страница 90: ...eight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quarantine of the People s Republic of China AQSIQ Men 15 33 08 Women 10 22 05 For more information about...

Страница 91: ... be created when the system breaks down facilitating cause analysis of the system breakdown The iBMC offers screen snapshots and videos simplifying routine preventive maintenance recording and auditing The FDM function supports component based precise fault diagnosis facilitating component fault locating and replacement The iBMC supports the reporting of alarms through syslog packets trap packets ...

Страница 92: ...he iBMC supports domain name system DNS and Lightweight Directory Application Protocol LDAP to implement domain management and directory service Intelligent power management The iBMC uses power capping to increase deployment density and uses dynamic energy saving to reduce operating expenditure License management By managing licenses you can use the features of the iBMC advanced edition in authori...

Страница 93: ... AC 2016 CISPR 32 2015 EN 55035 2017 CISPR 35 2016 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 EN 61000 3 2 2014 EN 61000 3 3 2013 RoHS 2011 65 EU EU 2015 863 EN 50581 2012 ErP 2009 125 EC ErP Directive Commission Regulation EU 2019 424 China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 10 Certifications Issue 03 202...

Страница 94: ...07 Ed 2 R 14Oct2014 CSA C22 2 60950 1 2007 Ed 2 A1 A2 Nigeria SONCAP IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Kingdom of Saudi Arabia KSA SASO IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Global CB IEC 60950 1 Japan VCCI VCCI 32 1 Saudi Nigeria Tanzania Uganda Kuwait Algeria Botswana Qatar Egypt Multi country_certificate IEC 6...

Страница 95: ...le Table A 1 SN description No Description 1 SN ID two characters which is 21 2 Material identification code eight characters that is processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 88 ...

Страница 96: ...indicate October to December respectively 5 Sequence number six characters 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model that is product name A 2 Operating Temperature Limitations Table A 2 Operating temperature limitations Configuration Max 30 C 86 F Max 35 C 95 F Max 40 C 104 F 8 x 2 5 drive pass through configuration 8 x SAS SATA All options supporteda Options supp...

Страница 97: ...CP 3 0 network adapters 100GE PCIe NICs 100GE IB cards 20 x 2 5 drive pass through configuration 4 x SAS SATA 16 x NVMe Options supported Processors of up to 250 W except the 8356H processors Options not supported GPU cards Options supported Processors of up to 205 W except the 8356H processors 100GE OCP 3 0 network adaptersc 100GE PCIe NICsc 100GE IB cardsc Options not supported GPU cards Not sup...

Страница 98: ...NICsc 100GE IB cardsc Options not supported GPU cards Not supported 25 x 2 5 drive EXP configuration 25 x SAS SATA Options supported Processors of up to 250 W except the 8356H processors Options not supported GPU cards Options supported Processors of up to 205 W except the 8356H processors 100GE OCP 3 0 network adaptersc 100GE PCIe NICsc 100GE IB cardsc Options not supported GPU cards Not supporte...

Страница 99: ... be affected You are advised to replace the fan module as soon as possible A 3 Nameplate Certified Model Usage Restrictions H24H 06 Global A 4 RAS Features The server supports a variety of Reliability Availability and Serviceability RAS features You can configure these features for better performance For details about the RAS features see FusionServer Pro 2488H V6 Server RAS Technical White Paper ...

Страница 100: ...ponent in position U51 on the mainboard CPU 2 component in position U134 on the mainboard CPU 3 component in position U52 on the mainboard CPU 4 component in position U53 on the mainboard N indicates the CPU number The value ranges from 1 to 4 CPUN MEM Temp CPU DIMM temperature DIMMs of CPU N N indicates the CPU number The value ranges from 1 to 4 SSD DiskN Temp SSD temperature SSD N indicates the...

Страница 101: ...re Component in position U94 on the mainboard PSN Fan Status PSU fan status PSU N indicates the PSU number The value is 1 or 2 PSN Temp Status PSU presence PSN Status PSU status Power Button Power button status Left mounting ear UID Button UID button status Left mounting ear AreaIntrusion Chassis cover status Chassis cover DISKN Drive status Drive N indicates the physical drive slot number FANN F ...

Страница 102: ...tes the component number SYS 3 3V_2 Mainboard 3 3 V voltage SYS 5V Mainboard 5 0 V voltage SYS 12V_1 Mainboard 12 0 V voltage the first output 12 V voltage detection for soft start CPU 1 VCC_5V SYS 12V_2 Mainboard 12 0 V voltage the second output 12 V voltage detection for soft start CPU 2 SYS 12V_3 Mainboard 12 0 V voltage the third output 12 V voltage detection for soft start CPU 3 SYS 12V_4 Mai...

Страница 103: ...PU DIMM voltage CPUN DDR VDDQ2 CPUN VSA CPU VSA voltage CPUN VCCIO CPU VCCIO voltage CPUN VCCIN CPU VCCIN voltage PwrOk Sig Drop Voltage drop status ACPI State ACPI status SysFWProgress Software process and system startup errors SysRestart Cause of system restart Boot Error Boot error Watchdog2 Watchdog Mngmnt Health Management subsystem health status RiserN Card Entity presence SAS Cable Entity p...

Страница 104: ...3 4 CPU UPI link fault diagnosis health status System Notice Hot restart reminder and fault diagnosis program information collection System Error System suspension or restart Check the background logs BMC Boot Up BMC startup events SEL Status SEL full or clearing events Op Log Full Operation log full or clearing events Sec Log Full Security log full or clearing events CPU Usage CPU usage Memory Us...

Страница 105: ...N Temp GPU temperature PCIeN Inlet Temp SDI card air inlet temperature PCIeN Cpu Temp SDI card CPU temperature PCIeN OP Temp PCIe card optical module temperature PCIeN NIC Temp PCIe card chip temperature PSN VIN Input voltage Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 98 ...

Страница 106: ...e the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet ...

Страница 107: ...er It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI system ...

Страница 108: ... A special computer that provides services for clients over a network system event log SEL Event records stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet chassis or subrack 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interconnect ...

Страница 109: ...Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Issue 03 2021 02 01 Copyright Huawei Technologies Co Ltd 102 ...

Страница 110: ...iation EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet GPIO General Purpose Input Output Huawei FusionServer Pro 2488H V6 Server Technical White Paper C...

Страница 111: ... IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC Intelligent Power Capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pro 2488H V6 Server ...

Страница 112: ...k Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK Power OK PWM pulse width modulation PXE Preboot Execution Environment Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Issue 03 2021 02 01 Copyright Huawei Technolo...

Страница 113: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extension T TACH tachometer signal TBT Turbo Boost...

Страница 114: ... unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 2488H V6 Server T...