Figure 5-41 Positions of PSUs
NO TE
● When one or two 900 W AC Titanium PSUs are configured and the input voltage ranges
from 100 V AC to 127 V AC, the output power decreases to 550 W.
● When one or two 2000 W AC Platinum PSUs are configured and the input voltage
ranges from 200 V AC to 220 V AC, the output power decreases to 1800 W.
● When one or two 3000 W AC Titanium PSUs are configured:
●
If the input voltage ranges from 100 V AC to 127 V AC, the output power
decreases to 1300 W.
●
If the input voltage ranges from 200 V AC to 220 V AC, the output power
decreases to 2500 W.
●
If the input voltage ranges from 220 V AC to 230 V AC, the output power
decreases to 2900 W.
5.9 Fan Modules
●
The server supports six fan modules.
●
The fan modules are hot-swappable.
●
N+1 redundancy is supported. That is, the server can work properly when a
single fan fails.
●
The fan speed can be adjusted.
●
Fan modules of the same part number (P/N code) must be used in a server.
Huawei FusionServer Pro 2488H V6 Server
Technical White Paper
5 Hardware Description
Issue 03 (2021-02-01)
Copyright © Huawei Technologies Co., Ltd.
62