background image

5

Data transmission status

indicator for a GE

electrical port

6

Connection status

indicator for a GE

electrical port

7

Data transmission status

indicator for the

management network

port

8

Connection status

indicator for the

management network

port

9

UID indicator

10

PSU indicator

 

Indicator Description

Table 5-3 Indicators on the rear panel

Indicator

Description

PSU indicator

● Off: No power is supplied.
● Blinking green at 1 Hz:

– The input is normal, the server is in standby

state, and the PSU is in MV6 mode (output

voltage is 6.7 V).

– The input is overvoltage or undervoltage.
– The PSU is in deep hibernation mode.

● Blinking green at 4 Hz: The firmware is being

upgraded online.

● Steady green: The power input and output are

normal.

● Steady orange: The input is normal, but no power

output is supplied.

NOTE

The possible causes of no power output are as follows:
● Power supply overtemperature protection
● Power output overcurrent or short-circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all devices)

UID indicator

The UID indicator helps identify and locate a device.
● Off: The device is not being located.
● Blinking blue: The device has been located and is

differentiated from other devices that have also

been located.

● Steady blue: The device is being located.

NOTE

You can turn on or off the UID indicator by pressing the UID

button or remotely running a command on the iBMC CLI.

Huawei FusionServer Pro 1288H V5 Server

Technical White Paper

5 Hardware Description

Issue 14 (2020-09-03)

Copyright © Huawei Technologies Co., Ltd.

17

Содержание FusionServer Pro 1288H V5

Страница 1: ...Huawei FusionServer Pro 1288H V5 Server V100R005 Technical White Paper Issue 14 Date 2020 09 03 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Страница 3: ...k which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance dete...

Страница 4: ...Refined the document for easy use 08 2018 09 06 Added drive configurations 07 2018 05 14 Updated the description of video cards 06 2018 04 18 Added TPM specifications Modified operating temperature specifications 05 2018 02 07 Added the NVMe configuration 04 2017 11 30 Added the specifications of the GPU and Broadcom SAS3508 RAID controller cards 03 2017 08 18 Added the description of the maximum ...

Страница 5: ...ntifier 22 5 4 2 Memory Subsystem Architecture 23 5 4 3 Memory Compatibility 24 5 4 4 Memory Installation Guidelines 26 5 4 5 Memory Installation Positions 27 5 4 6 Memory Protection Technologies 28 5 5 Storage 29 5 5 1 Drive Configurations 29 5 5 2 Drive Numbering 30 5 5 3 Drive Indicators 30 5 5 4 RAID Controller Card 32 5 6 Network 32 5 6 1 FlexIO Cards 32 5 7 I O Expansion 35 5 7 1 PCIe Cards ...

Страница 6: ...ons 54 8 1 Safety Instructions 54 8 2 Maintenance and Warranty 57 9 System Management 58 10 Certifications 60 A Appendix 62 A 1 Product SN 62 A 2 Operating Temperature Limitations 63 A 3 Nameplate 64 A 4 RAS Features 65 A 5 Sensor List 67 B Glossary 72 B 1 A E 72 B 2 F J 73 B 3 K O 73 B 4 P T 73 B 5 U Z 74 C Acronyms and Abbreviations 75 C 1 A E 75 C 2 F J 76 C 3 K O 77 C 4 P T 78 C 5 U Z 80 Huawe...

Страница 7: ...puting distributed storage big data processing enterprise or telecom applications and other complex workloads The compact and reliable 1288H V5 features low power consumption high scalability easy deployment and simplified management NOTE For details about the 1288H V5 nameplate information see A 3 Nameplate Figure 1 1 1288H V5 with 8 drives Huawei FusionServer Pro 1288H V5 Server Technical White ...

Страница 8: ...OS vendors to better use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications The Cascade Lake processors support Intel Deep Learning Boost vector neural network instructions VNNI to improve the performance of deep learning applications The server supports double dat...

Страница 9: ...or the servers used in China Huawei provides a 10 hour a day 7 day a week support program Service requests will be handled the next business day Optional service upgrades are available Huawei provides a three year warranty for parts replacement and repair for the servers used outside China Huawei provides a 9 hour a day 5 day a week support program Service requests will be handled the next busines...

Страница 10: ...dress subnet mask and gateway and IPv6 addresses IPv6 address prefix length and gateway for this port Energy Efficiency The 80 Plus Platinum power supply units PSUs of multiple power ratings provide 94 power efficiency at 50 load The server supports active standby power supplies and high voltage DC HVDC for improved power supply efficiency Efficient voltage regulator down VRD power supplies for bo...

Страница 11: ...an modules 5 Front drive backplane 6 Drives 7 DVD drive 8 Indicator board 9 VGA board 10 Heat sinks 11 Processors 12 DIMMs 13 TPM TCM 14 Screw in RAID controller card 15 Mainboard 16 FlexIO card Huawei FusionServer Pro 1288H V5 Server Technical White Paper 3 Physical Structure Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 5 ...

Страница 12: ...17 PCIe riser module 1 18 PCIe riser module 2 Huawei FusionServer Pro 1288H V5 Server Technical White Paper 3 Physical Structure Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 6 ...

Страница 13: ... processors through PCIe buses to provide ease of expandability and connection The RAID controller card on the mainboard connects to CPU 1 through PCIe buses and connects to the drive backplane through SAS signal cables A variety of drive backplanes are provided to support different local storage configurations The LBG 2 Platform Controller Hub PCH supports Huawei FusionServer Pro 1288H V5 Server ...

Страница 14: ...OM ports The server uses Hi1710 management chip and supports a video graphic array VGA port a management network port and a debug serial port Huawei FusionServer Pro 1288H V5 Server Technical White Paper 4 Logical Structure Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 8 ...

Страница 15: ...pansion 5 8 PSUs 5 9 Fans 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 4 x 3 5 drive configuration Figure 5 1 Front view 1 Drives 2 Slide out label plate with an SN label Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 9 ...

Страница 16: ...onfiguration Figure 5 3 Front view 1 Drives 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons Positions 4 x 3 5 drive configuration Figure 5 4 Indicators and buttons on the front panel Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 10 ...

Страница 17: ...the front panel 1 Fault diagnosis LED 2 Health status indicator 3 LOM port 1 connection status indicator 4 LOM port 2 connection status indicator 5 LOM port 3 connection status indicator 6 LOM port 4 connection status indicator 7 NMI button 8 Power button indicator 9 UID button indicator 10 x 2 5 drive configuration Figure 5 6 Indicators and buttons on the front panel 1 Power button indicator 2 Fa...

Страница 18: ... is not powered on Steady green The device is powered on Blinking yellow The power button is locked The power button is locked when the iBMC is starting Steady yellow The device is ready to power on Power button When the device is powered on you can press this button to gracefully shut down the OS When the device is powered on holding down this button for 6 seconds will forcibly power off the devi...

Страница 19: ...linking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly NMI button A non maskable interrupt NMI is generally triggered to stop the OS for debugging To trigger an NMI press this button or click the button on the iBMC WebUI NOTICE Press the NMI button only when the OS is ab...

Страница 20: ...powered off even if the service system is powered off As long as the LOM ports are properly connected to other working network devices the network ports will remain connected and the indicators are on 5 1 3 Ports Port Positions 4 x 3 5 drive configuration Figure 5 7 Ports on the front panel 1 USB 2 0 port 2 USB 3 0 port 3 VGA port 8 x 2 5 drive configuration Figure 5 8 Ports on the front panel 1 U...

Страница 21: ...USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected USB 3 0 1 Note The number of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5 2 Rear Panel Huawei FusionServer Pro 1288H V5 Server Technical White Pap...

Страница 22: ...icator Data transmission status indicator for a 10GE optical port 2 Data transmission rate indicator for a 10GE optical port 3 Data transmission rate indicator for a 10GE electrical port 4 Connection status indicator Data transmission status indicator for a 10GE electrical port Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei...

Страница 23: ...Steady green The power input and output are normal Steady orange The input is normal but no power output is supplied NOTE The possible causes of no power output are as follows Power supply overtemperature protection Power output overcurrent or short circuit Output overvoltage Short circuit protection Device failure excluding failure of all devices UID indicator The UID indicator helps identify and...

Страница 24: ...E electrical port Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected Data transmission rate indicator for a 10GE electrical port Off The network port is not connected Steady green The data transmission rate is 10 Gbit s Steady yellow The data transmission rate is 1 Gbit s Connection status indicator Data transmission s...

Страница 25: ...ockets Port Description Table 5 4 Ports on the rear panel Port Type Quantity Description Optional 10GE optical port 10GE SFP 2 10GE LOM service ports optical Use the optical or electrical ports based on service requirements Optional 10GE electrical port 10GE BASE T 2 10GE LOM service ports electrical Use the optical or electrical ports based on service requirements GE electrical port 1000BASE T 2 ...

Страница 26: ...n USB port USB 3 0 2 Used to connect to a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected PSU socket 2 Used to connect to the power distribution unit PDU in the cabinet You can select the number of power supply units PSUs as required NOTE When determining the quantity of...

Страница 27: ...ted to power over Ethernet PoE devices such as a switch with PoE enabled Connecting a LOM port to a PoE device may cause link communication failure or even damage the NIC The electrical LOM ports do not support SR IOV Forcibly powering off a server will cause intermittent NC SI disconnection and disable the Wake on LAN WOL function of the LOM ports To restore the NC SI connection refresh the iBMC ...

Страница 28: ...ou can determine the memory module properties based on the label attached to the memory module Figure 5 14 Memory identifier Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 22 ...

Страница 29: ...P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 2 Memory Subsystem Architecture The 1288H V5 provides 24 memory slots Each processor integrates six memory channels Install DIMMs in primary memory channels first If the primary memory channel is not populated the DIMMs in secondary memory channels cannot be used Table 5 6 Memory channels CPU Memory Channel Memory Slot CPU 1 A primary DIMM000 A A DIMM001 ...

Страница 30: ...101 G B primary DIMM110 B B DIMM111 H C primary DIMM120 C C DIMM121 I D primary DIMM130 D D DIMM131 J E primary DIMM140 E E DIMM141 K F primary DIMM150 F F DIMM151 L 5 4 3 Memory Compatibility Observe the following rules when configuring DDR4 DIMMs Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 24 ...

Страница 31: ...B socket The total memory capacity is the sum of the capacity of all DDR4 DIMMs NOTICE The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs Use the Computing Product Compatibility Checker to determine the capacity type of a single DIMM The maximum number of DIMMs supported by a server varies depending on the CPU type memory type rank quantity and operating volt...

Страница 32: ...cessor is used the maximum operating speed of a DIMM can reach 2666 MT s only 5 4 4 Memory Installation Guidelines Observe the following when configuring DDR4 DIMMs Install DIMMs only when corresponding processors are installed Do not install LRDIMMs and RDIMMs in the same server Install filler DIMMs in vacant slots Observe the following when configuring DDR4 DIMMs in specific operating mode Memor...

Страница 33: ...emory Installation Positions A 1288H V5 supports a maximum of 24 DDR4 DIMMs To maximize the performance balance the total memory capacity between the installed processors and load the channels similarly whenever possible NOTICE At least one DDR4 DIMM must be installed in the memory slots corresponding to CPU 1 Figure 5 15 Memory slots Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5...

Страница 34: ...emory Protection Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring SDDC SDDC 1 Rank sparing mode Static virtual lockstep Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 28 ...

Страница 35: ...rt only SAS SATA drives 1 x RAID controller card PCHa 10 x 2 5 drive configuration 1 10 Slots 0 and 1 support only SAS SATA drives Slots 2 and 3 support SAS SATA NVMe drives Slots 4 to 9 support only NVMe drives 1 x RAID controller card PCHa 10 x 2 5 drive configuration 2 10 Slots 0 to 9 support only SAS SATA drives 1 x RAID controller cardb 10 x 2 5 drive configuration 3 10 Slots 0 to 5 support o...

Страница 36: ...e Computing Product Compatibility Checker to determine the components to be used 5 5 2 Drive Numbering 4 x 3 5 drive configuration Figure 5 18 Drive numbering 8 x 2 5 drive configuration Figure 5 19 Drive numbering 10 x 2 5 drive configuration Figure 5 20 Drive numbering 5 5 3 Drive Indicators SAS SATA Drive Indicators Figure 5 21 SAS SATA drive indicators Huawei FusionServer Pro 1288H V5 Server T...

Страница 37: ...n The drive is faulty NVMe Drive Indicators Figure 5 22 NVMe drive indicators If the VMD function is enabled and the latest VMD driver is installed the NVMe drives support surprise hot swap Table 5 10 Description of NVMe drive indicators VMD enabled Activity Indicator Green Fault Indicator Yellow Description Off Off The NVMe drive cannot be detected Steady on Off The NVMe drive is working properly...

Страница 38: ... NVMe drive is removable Steady on Off Steady on The NVMe drive is faulty 5 5 4 RAID Controller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used For details about the RAID controller card see Huawei V5 Server RAID C...

Страница 39: ... SM212 i350 GE electrical port 4 SM233 X540 10GE electrical port 2 SM251 CX3 56G IB optical port 2 SM252 CX3 56G IB optical port 1 SM380 CX4 25GE optical port 2 Indicator Positions SM210 SM212 with four GE electrical ports Figure 5 23 SM210 SM212 network port indicators SM211 with two GE electrical ports Figure 5 24 SM211 network port indicators SM233 with two 10GE electrical ports Huawei FusionSe...

Страница 40: ...Description Table 5 13 Description of FlexIO card indicators Port Type Indicator Description GE electrical port Data transmission status indicator Off No data is being transmitted Blinking yellow Data is being transmitted Connection status indicator Off The network port is not connected Steady green The network port is properly connected Huawei FusionServer Pro 1288H V5 Server Technical White Pape...

Страница 41: ...ta transmission rate is 25 Gbit s Steady yellow The data transmission rate is 10 Gbit s Connection status indicator Data transmission status indicator Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected 56G IB optical port Connection status indicator Off No physical link is set up Blinking green The physical link is abn...

Страница 42: ... slots PCIe riser module 1 provides slot 1 PCIe riser module 2 provides slots 2 and 3 NOTE If NVMe drives are configured slot 1 can be installed with an NVMe adapter only No PCIe card can be installed in slot 1 If GPU PCIe cards are used up to 2 HHHL single slot GPU x16 cards can be installed in slots 1 and 2 Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issu...

Страница 43: ...dules 5 7 3 PCIe Slot Description NOTE The PCIe slots mapping to a vacant CPU socket are unavailable Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 37 ...

Страница 44: ...D F indicates the B D F of an internal PCIe root port of the processor Device B D F indicates the B D F displayed on the OS of an onboard or extended PCIe device The PCIe x16 slots are backward compatible with PCIe x8 PCIe x4 and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half length FHHL PCIe ...

Страница 45: ...nfigured with one or two 1500 W Platinum AC PSUs When the input voltage is from 100 V AC to 132 V AC the output power drops to 1000 W Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs Figure 5 31 PSU positions 5 9 Fans The server supports seven fan modules The fan modules are hot swappable The server tolerates failure of a single fan The fan speed can be adjusted The same model of fan modules m...

Страница 46: ...Figure 5 32 Fan module positions 5 10 Boards Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 40 ...

Страница 47: ... Management network port 5 GE electrical port 6 GE electrical port 7 VGA connector VGA CONN J112 8 10GE optical port 10GE PORT2 J132 or 10GE electrical port 10GE PORT2 J101 a Huawei FusionServer Pro 1288H V5 Server Technical White Paper 5 Hardware Description Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 41 ...

Страница 48: ...N6 J142 22 Fan 5 connector 1U FAN5 J143 23 Fan 4 connector 1U FAN4 J102 24 Fan 3 connector 1U FAN3 J103 25 Fan 2 connector 1U FAN2 J104 26 Fan 1 connector 1U 2U FAN1 J105 27 Drive backplane connector HDD BP CONN J162 28 Drive backplane power connector 1 HDD BP PWR1 J128 29 CPU 2 slimline A connector CPU2 SLIMLINE A J140 30 CPU 2 slimline B connector CPU2 SLIMLINE B J139 31 PSU 2 connector J157 32 ...

Страница 49: ... for restoring default iBMC settings 5 10 2 Drive Backplane 4 x 3 5 drive backplane Figure 5 34 4 x 3 5 drive backplane BOM 03024NKB 1 Backplane indicator signal cable connector J6 2 SATA signal connector PORT3 J5 3 SATA signal connector PORT2 J4 4 SATA signal connector PORT1 J3 5 Power connector HDD POWER J24 6 SATA signal connector PORT0 J2 7 Backplane signal cable connector HDD_BP J1 8 x 2 5 dr...

Страница 50: ...e A connector SLIM A J8 8 Slimline B connector SLIM B J9 9 Power connector HDD POWER J1 10 Backplane signal cable connector HDD BP J22 10 x 2 5 drive backplane 2 Figure 5 37 10 x 2 5 drive backplane 2 BOM 03025CYT 1 Slimline B connector SLIM B J29 2 Slimline A connector SLIM A J28 3 mini SAS HD connector PORT C J23 4 mini SAS HD connector PORT B J3 5 mini SAS HD connector PORT A J2 6 Power connect...

Страница 51: ...y controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Two UPI buses between processors providing up to 10 4GT s transmission per channel Up to 28 cores 2 7 GHz Max 3 8 GHz four cores Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain specif...

Страница 52: ... different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain specific information Huawei FusionServer Pro 1288H V5 Server Technical White Paper 6 Product Specifications Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 46 ...

Страница 53: ...mware com s article 1033696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applications the M 2 SSD will wear out in a short time Use enterprise level high endurance HE SSDs or HDDs for data storage The M 2 SSD is not recommended for write intensive service software due to poor endurance Do no...

Страница 54: ... be connected to PoE devices such as a switch with PoE enabled Connecting such a port to a PoE device may cause link communication failure or even damage the NIC Forcibly powering off a server will cause intermittent NC SI disconnection and disable the WOL function of the LOM ports To restore the NC SI connection refresh the iBMC WebUI I O expansion 5 PCIe 3 0 slots One slot dedicated for a screw ...

Страница 55: ...e mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by the operating system is provided If the chassis provides the front and rear VGA ports but only ...

Страница 56: ...rver complies with ASHRAE Class A2 the maximum operating temperature decreases by 1 C 1 8 F for every increase of 300 m 984 25 ft in altitude above 900 m 2952 76 ft If the server complies with ASHRAE Class A3 the maximum operating temperature decreases by 1 C 1 8 F for every increase of 175 m 574 15 ft in altitude above 900 m 2952 76 ft If the server complies with ASHRAE Class A4 the maximum opera...

Страница 57: ...73 4 F in accordance with ISO 7779 ECMA 74 and reported in accordance with ISO 9296 ECMA 109 Idle LWAd 5 92 Bels LpAm 42 3 dBA Operating LWAd 6 14 Bels LpAm 46 3 dBA NOTE The noise generated during operation varies depending on the server configuration load and ambient temperature 6 3 Physical Specifications Table 6 3 Physical specifications Category Description Dimensions H x W x D Chassis with 3...

Страница 58: ...s to cabinets with a distance of 610 mm to 914 mm 24 02 in to 35 98 in between the front and rear mounting bars Weight in full configuration Maximum net weight Server with 8 x 2 5 drives 17 3 kg 38 15 lb Server with 4 x 3 5 drives 18 4 kg 40 57 lb Server with 10 x 2 5 drives 17 8 kg 39 25 lb Packaging materials 5 kg 11 03 lb Power consumption The power consumption parameters vary with hardware con...

Страница 59: ...ic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact Huawei sales personnel to apply for POC tests in the pre sales phase to determine detailed software and hardware configurations If the customer has requirements on hardware performance consist...

Страница 60: ... a forklift Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operate...

Страница 61: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 1288H V5 Server Technical White Paper 8 Sa...

Страница 62: ...e handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury If the device is configured with active and standby PSUs connect power cables of active and standby PSUs to different power distribution units PDUs to ensure reliable system operating Properly ground a device befo...

Страница 63: ... a number of organizations Table 8 1 Maximum weight one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quaran...

Страница 64: ...nd text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Feature Description Management interface Integrates with any standard management system through the following interfaces or protocols IPMI CLI HTTPS SNMP Redfish Fault detection Detects and accurately locates faults in hardware for example...

Страница 65: ...erations Fault reproduction Reproduces faults to help diagnose them quickly Screen snapshots and screen videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services significantly simp...

Страница 66: ... AC 2016 CISPR 32 2015 EN 55035 2017 CISPR 35 2016 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 EN 61000 3 2 2014 EN 61000 3 3 2013 RoHS 2011 65 EU EU 2015 863 EN 50581 2012 ErP 2009 125 EC ErP Directive Commission Regulation EU 2019 424 China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 Huawei FusionServer Pro 1288H V5 Server Technical White Paper 10 Certifications Issue 14 202...

Страница 67: ...07 Ed 2 R 14Oct2014 CSA C22 2 60950 1 2007 Ed 2 A1 A2 Nigeria SONCAP IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Kingdom of Saudi Arabia KSA SASO IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Global CB IEC 60950 1 Japan VCCI VCCI 32 1 Saudi Nigeria Tanzania Uganda Kuwait Algeria Botswana Qatar Egypt Multi country certificate IEC 6...

Страница 68: ...le Table A 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 1288H V5 Server Technical White Paper A Appendix Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 62 ...

Страница 69: ...ctively 5 Sequence number six characters 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model that is product name A 2 Operating Temperature Limitations Table A 2 Operating temperature limitations Configuratio n Max 35 C 95 F Max 40 C 104 F Max 45 C 113 F 4 x 3 5 drive configuration All options supported Options not supported Platinum 8180 8168 8280 8280L 8280M 8268 and Gold...

Страница 70: ... cards 10 x 2 5 drive configuration SP351 BC51IBMB IB cards supported Not supported Not supported NOTE When a single fan is faulty The maximum operating temperature is 5 C 9 F lower than the rated value System performance will be affected if GPU cards are configured If the server is configured with ten 2 5 inch drives and SP351 BC51IBMB IB cards the maximum operating temperature supported is 30 C ...

Страница 71: ...ity Protection Detects memory command and address errors Memory Demand and Patrol Scrubbing Corrects errors upon detection If these errors are not corrected promptly uncorrectable errors may occur Memory Mirroring Improves system reliability Single Device Data Correction Provides a single device multi bit error correction capability to improve memory reliability Device Tagging Degrades and rectifi...

Страница 72: ...ds the error information to the OS over the APEI of the Advanced Configuration and Power Interface ACPI and locates the error unit improving system availability Error Injection Support Injects errors to verify various RAS features Machine Check Architecture Provides software recovery for uncorrectable errors to improve system availability eMCA Gen2 Improves system availability OOB access to MCA re...

Страница 73: ...e is 1 or 2 CPUN DTS CPU DTS value CPUN N indicates the CPU number The value is 1 or 2 CPUN Margin CPU Margin CPUN N indicates the CPU number The value is 1 or 2 CPUN VDDQ Temp CPU VDDQ temperature Mainboard N indicates the CPU number The value is 1 or 2 CPUN VRD Temp CPU VRD temperature Mainboard N indicates the CPU number The value is 1 or 2 CPUN MEM Temp CPU DIMM temperature DIMMs of CPU N N in...

Страница 74: ...e Mainboard N indicates the CPU number The value is 1 or 2 CPUN VCCIO CPU VCCIO voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VMCP CPU VMCP voltage Mainboard N indicates the CPU number The value is 1 or 2 PCH VPVNN PCH VPVNN voltage Mainboard PCH PRIM 1V05 PCH PRIM voltage Mainboard CPUN VCCP CPU VCCP voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN DDR...

Страница 75: ...put power PSUN N indicates the PSU number The value is 1 or 2 PCH Status PCH chip fault diagnosis health status Mainboard CPUN QPI Link CPU QPI link fault diagnosis health status Mainboard or CPUN N indicates the CPU number The value is 1 or 2 CPUN Prochot CPU Prochot CPUN N indicates the CPU number The value is 1 or 2 CPUN Status CPU status CPUN N indicates the CPU number The value is 1 or 2 CPUN...

Страница 76: ...nboard PwrOn TimeOut Power on timeout Mainboard PwrCap Status Power capping status Mainboard HDD Backplane Entity presence Drive backplane HDD BP Status Drive backplane health status Drive backplane RiserN Card Entity presence Riser card N N indicates the riser card number The value is 1 or 2 FANN F Presence Fan presence Fan module N N indicates the fan module number The value ranges from 1 to 7 F...

Страница 77: ...anges from 0 to 9 LOM P1 Link Down LOM LOM LOM P2 Link Down LOM LOM LOM P3 Link Down LOM LOM LOM P4 Link Down LOM LOM PCIe RAID Temp PCIe RAID controller card temperature PCIe RAID controller card M2 Temp PCIe Maximum temperature of all M 2 drives of the RAID controller card PCIe RAID controller card PCIe OP Temp PCIe card optical module temperature PCIe card PCIe NIC Temp PCIe card chip temperatu...

Страница 78: ...e the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet ...

Страница 79: ...rver It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syste...

Страница 80: ...ecial computer that provides services for clients over a network system event log SEL A non volatile area and interfaces used to store system events for later fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor intercon...

Страница 81: ...Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 1288H V5 Server Technical White Paper C Acronyms and Abbreviations Issue 14 2020 09 03 Copyright Huawei Technologies Co Ltd 75 ...

Страница 82: ...an Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet Huawei FusionServer Pro 1288H V5 Server Technical White Paper C Acr...

Страница 83: ...ternet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pr...

Страница 84: ... Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect Huawei FusionServer Pro 1288H V5 Server Technical White Paper C Acronyms and Abbreviations Issue 14 2020 09 03 Copyright Huawei Techno...

Страница 85: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boos...

Страница 86: ... Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 1288H V5 Server Technical Whit...

Отзывы: