eSpace IAD104H
Quick Start
5
Configuration (EMS)
Issue 10 (2019-04-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
42
Operation
Command
Default Value
Set the physical
serial number
(which consists
of 1 to 64
characters)
physical-serial-num
Unique physical
serial number of
each IAD.
Step 3
Run the
write
command to save the settings.
Run the
display nms
command to view status of the IAD
registering to the UCEMS.
TERMINAL#
display nms
the config is IP /*It indicates that the address of the
UCEMS has set through a domain name.*/
-------------------------------------------------------
-----------------
type IP address status
primary 192.168.1.201 normal
secondary <unconfig> unconfiged
-------------------------------------------------------
-----------------
get community : ********
set community : ********
trap community : ********
trap port : 162
nms access value: Enable
register nms ip : 192.168.1.201
register state : succeed
handshake : on
handshake time : 30 S
register switch : on
If the "register state" field displays "succeed", it indicates that
the IAD has registered to the UCEMS successfully.
----End