Postrequisite
If the software version of the equipment is incorrect, upgrade the software version by referring
to the
APM Operator Guide
.
4.5 Checking the Running Status
This chapter describes how to check the running status of the ePico3801.
Prerequisite
The ePico3801 hardware is in normal state, the transmission is available, and the running
software version is correct.
Procedure
Step 1
Check the equipment alarm on the AP Manager (APM) and clear the existing alarm by referring
to the
APM Operator Guide
.
If...
Then...
An alarm is generated
Clear the alarm according to
Help
.
An active alarm cannot
be cleared
4.7 Data Sheet for Commissioning
----End
4.6 Testing Services
This chapter describes how to test the services provided by the ePico3801 to ensure that the
ePico3801 can provide basic telecommunication services such as CS and PS services.
Prerequisite
l
The ePico cell is set up.
l
Two functional UEs (UE 1 and UE 2) are ready.
l
The IMSIs of UE 1 and UE 2 are added to the ePico permission list.
l
A functional fixed-line phone is ready.
l
The CS and PS domains in the core network are functional.
Testing Items
describes the basic items in the ePico3801 service test.
4 Commissioning the ePico3801
ePico3801
User Guide
4-8
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009–09–23)