Procedure
Step 1
log in to the converged switching plane CLI.
Step 2
Run the following command on the CLI of the converged switching plane to check the current
version of the converged switching plane:
<HUAWEI>
display version
The command output is as follows:
Huawei Versatile Routing Platform Software
VRP (R) software, Version 8.120 (OSCA V100R005C60)
Copyright (C) 2012-2016 Huawei Technologies Co., Ltd.
HUAWEI OSCA uptime is 0 day, 3 hours, 32 minutes
CX320(Master) 1 : uptime is 0 day, 3 hours, 31 minutes
StartupTime 2016/07/24 11:30:44
Memory Size : 2048 M bytes
Flash Size : 1024 M bytes
CX320 version information
1. PCB Version : CX320 VER A
2. MAB Version : 0
3. Board Type : CX320
4. CPLD1 Version : 6.07
5. BIOS Version : 2.49
6. Software Version : 5.70
Software Version
indicates the current software version.
Step 3
Check whether the software version is consistent with the desired one.
l
If yes, go to
.
l
If no, contact Huawei technical support.
Step 4
Query the alarms of the converged switching plane.
<HUAWEI>
display alarm active
The command output is as follows:
1:Critical 2:Major 3: Minor 4:Warning
------------------------------------------------------------------
Sequence AlarmId Severity Date Time Description
------------------------------------------------------------------
The parameters are described as follows:
l
Critical
: critical alarm
l
Major
: major alarm
l
Minor
: minor alarm
l
Warning
: warning alarm
l
Sequence
: alarm sequence
l
AlarmId
: alarm ID
l
Severity
: alarm severity
l
Date Time
: date and time at which an alarm is generated
l
Description
: alarm description
If no information is displayed, no alarm is generated.