background image

Huawei AR532 Router & AR-DCM-Pa 
User Manual 

2 Hardware Installation 

 

Issue 01 (2016-09-20) 

Huawei Proprietary and Confidential                                     

Copyright © Huawei Technologies Co., Ltd. 

19 

 

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 

Changes or modifications not expressly approved by the party responsible for compliance 
could void the user's authority to operate the 

equipment. 

 

---End 

Содержание AR532

Страница 1: ...Huawei AR532 Router AR DCM Pa User Manual Issue 01 Date 2016 09 20 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...e customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject...

Страница 3: ... installation instructions covering the equipment appearance and specifications installation preparations equipment installation procedure and cable connection This document is intended for Hardware installation engineers Onsite maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates an imminently hazardous situati...

Страница 4: ...prietary and Confidential Copyright Huawei Technologies Co Ltd iii Symbol Description Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury ...

Страница 5: ...formance deterioration or unanticipated results NOTICE is used to address practices not related to personal injury Calls attention to important information best practices and tips NOTE is used to address information not related to personal injury equipment damage and environment deterioration Change History Changes between document issues are cumulative The latest document issue contains all the c...

Страница 6: ...1 2 Appearance 1 1 1 3 Indicator Description 3 1 1 4 Interface Description 5 1 1 5 Technical Specifications 7 1 2 Modules 8 1 2 1 PLC Module 8 2 Hardware Installation 11 2 1 Preparations 11 2 1 1 Safety Precautions 11 2 1 2 Checking the Installation Environment 12 2 1 3 Preparing Installation Tools 13 2 2 Installing an AR532 Router 14 2 2 1 Installing the Router in a Three Meter Box 14 2 2 2 Optio...

Страница 7: ...escription About This Chapter 1 1 Chassis 1 2 Modules 1 3 Cables 1 1 Chassis 1 1 1 Version Mapping Table 1 1 lists the mapping between the AR532 router and software versions Table 1 1 Mapping between theAR532 router and software versions Router Model Software Version AR532 V200R008C20 and later versions 1 1 2 Appearance Figure 1 1 shows the appearance of the AR532 router ...

Страница 8: ...Huawei AR532 Router AR DCM Pa User Manual 1 Hardware Description Issue 01 2016 09 20 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 Figure 1 1 AR532 appearance ...

Страница 9: ...32 interface 5 Operation keys 6 Backup battery holder NOTE To ensure optimal performance of the battery it is recommended that the battery be used within a temperature range of 10 C to 60 C 14 F to 140 F 7 3G module slot 8 PLC RF module slot 9 Auxiliary terminals NOTE Terminals 15 to 18 A1 B1 A2 B2 are used for RS485 interfaces 10 AC power socket 11 GE combo interface 12 GE electrical interface Re...

Страница 10: ...0 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 Figure 1 2 Indicators on theAR532 Numbe r Indicator Color Description 1 RUN ALM Red and green Slow blinking green The system is running properly Fast blinking green The system is powering on or is restarting ...

Страница 11: ...trical interface 3 5 RS485 interface indicators RS4850 and RS4851 Orange Steady on The corresponding RS485 link is available but the interface is not connected or is not transmitting or receiving data Fast blinking The corresponding RS485 link is available and is transmitting or receiving data Off The corresponding RS485 link is not configured or has failed 1 1 4 Interface Description USB Interfac...

Страница 12: ...nterface connection mode Ethernet interfaces of most network interface cards NICs are MDI interfaces MDIX stands for medium dependent interface crossover a version of MDI MDIX interfaces are usually used on HUB or LAN switch Frame format Ethernet_II Ethernet_SAP Ethernet_SNAP Network protocol IP Cable type Ethernet Cable 3G WCDMA Antenna Interface The 3G WCDMA antenna interface connects to a 3G WC...

Страница 13: ...en one of the Ethernet interfaces is working the other interface is shut down A GE electrical interface 10 100 1000 Mbit s auto sensing transmits and receives services at 10 Mbit s 100 Mbit s or 1000 Mbit s The GE optical interface 100 1000 Mbit s auto sensing transmits and receives services at 100 Mbit s or 1000 Mbit s By default a combo interface works as an electrical interface and uses an Ethe...

Страница 14: ... 456 V AC Power consumption Maximum power consumption 12 5 W Environment parameters Operating environment temperature 25 C to 70 C 13 F to 158 F NOTE The operating temperature cannot exceed 65 C 149 F when a 3G module is used in the router Storage temperature 40 C to 85 C 40 F to 185 F Operating relative humidity 5 to 95 noncondensing Operating altitude 5000 m 16404 ft 1 2 Modules 1 2 1 PLC Module...

Страница 15: ...ency band and serial number identifier SNID of the PLC module in the same way Show the SNID The indicator keeps on for 500 ms and then off for 500 ms The number of alternations between the on and off states depends on the SNID value After showing the SNID the indicator stays off for 5s Show the working frequency band The indicator keeps on for 2s and then off for 2s This process lasts for 4s to 16...

Страница 16: ...cription show the SNID again 3 RX Green Startup stage blinks at variable frequencies Operation stage steady on when data is being received and off when no data is received Ordering Information To place an order contact the Huawei local office Table 1 6 provides the ordering information Table 1 6 Ordering information Part Number Module Name Description 50030153 AR DCM Pa PLC module ...

Страница 17: ... your safety and protect the equipment from damage Safety precautions provided in this document may not cover every eventuality so remain mindful of safety at all times Only trained and qualified personnel should be allowed to install operate or maintain the equipment General Safety Guidelines Always take precautions against ESD whenever you handle the equipment For example wear ESD gloves or an E...

Страница 18: ...otect personal and equipment safety ground the equipment before connecting it to a power source Mechanical Safety Protect the equipment from collision during transportation and unpacking If damage is found on the shell of the equipment which may be caused by collision during movement or installation contact the equipment supplier immediately Do not power on the equipment in this case Place the equ...

Страница 19: ...voidance There must be no acidic alkaline or other corrosive gases in the installation site Surge protection Deploy signal cables on internal walls Do not route cables aerially in outdoor environments Keep signal cables away from power cables and surge protection devices Electromagnetic environment See Electromagnetism Requirements for the Equipment Room 2 1 3 Preparing Installation Tools The foll...

Страница 20: ...hree Meter Box Tools and Accessories Three meter box purchased separately Three phase four pin power cable M4 screws two Flat head screwdriver Phillips screwdriver The three phase four pin power cable and M4 screws are included in the accessory package of the three meter box Procedure Step 1 Use a Phillips screwdriver to loosen the screws at two sides of the lower protection cover on the AR532 rou...

Страница 21: ...Step 2 Hang the AR532 router on the screw in the meter box by the mounting hole at the back of the router and use two M4 screws to secure the router in the meter box Step 3 Remove power cable cover and connect the three phase four pin power cable to the AR532 router and circuit breaker The power terminals on the AR532 router are La Lb Lc and N from left to right ...

Страница 22: ... Pa User Manual 2 Hardware Installation Issue 01 2016 09 20 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 16 Step 4 Install the power cable cover and then the lower protection cover to the AR532 router ...

Страница 23: ...es Co Ltd 17 End 2 2 2 Optional Installing a PLC Module in the Router Tools and Accessories PLC module purchased separately Phillips screwdriver Procedure Step 1 Use a Phillips screwdriver to loosen the screw at the right side of the upper protection cover on the AR532 router open the upper protection cover and install the PLC module into the router ...

Страница 24: ...ser Manual 2 Hardware Installation Issue 01 2016 09 20 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 18 Step 2 Close the upper protection cover install the lower protection cover and tighten screws on them ...

Страница 25: ...part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment End ...

Отзывы: