The screws provided for ceiling-mounting of APs are 30 mm long and can be used to fix an
AP on a ceiling not thicker than 15 mm. To install APs on thicker ceilings, you need to
purchase longer screws.
Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above
and around the AP for maintenance.
2.5.3 T-rail Mounting
1.
Remove two ceiling tiles around the T-rail, use screws to fix the adjustable buckle to the
mounting bracket, hook the adjustable buckle to the T-rail, and secure the screw on the
adjustable buckle to fasten the mounting bracket and T-rail.
1. T-rail
2. Adjustable buckle
3. M3x6 screws
2.
Hang the AP on the mounting holes by aligning the mounting screws at the rear of the
AP with the mounting holes on the bracket and push the AP horizontally to secure the
AP.