DBS3900 LampSite
Installation Guide
8 Installing a pRRU3902 or pRRU3911 or
pWIFI
Issue 08 (2016-05-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
115
Installing on a keel
The pRRU can be installed on a keel of U-shape, T-shape, or H-shape. For the keels of other
shapes, they are determined based on the onsite requirements.
Table 8-5
Keel-mounted installation suggestion
Installation
Mode
Requirements
Mounting Brackets
Installation
Diagram
Installing the
pRRU on a
keel
For details,
see 8.3.6
Installing a
pRRUon a
Keel.
The keel is in
U-shape, T-shape,
H-shape, or other
shapes.
1.
Plate
2.
U-shaped metal plate
3.
Bolt (M4 x 35)
4.
Bolt (M4 x 60)
shows the pRRU
installed on a
U-shaped keel.
Installing on a on steel hangers
Either M6 or M8 steel hangers can be used for installation.
Table 8-6
Steel hangers installation suggestion
Installation
Mode
Requirements
Mounting Brackets
Installation
Diagram
Installing the
pRRU on a
steel hangers
For details,
see 8.3.7
Installing a
pRRU on
Steel
Hangers.
Either M6 or M8
steel hangers can be
used for installation.
1.
Plate
2.
U-shaped metal plate
3.
Bolt (M4 x 35)
4.
Bolt (M4 x 60)
Cabinet
In the outside scenario, pRRU3902 should be installed in the cabinet.