No.
Port (Silk
Screen)
Function
Description
1
RF1, RF2
Reserved
Reserved.
2
12V OUT
12 V DC output
Provides 12 V DC power supply with a maximum
current of 100 mA.
3
12V IN
12 V DC input
Connects to the power adapter.
4
USB
USB port
Connects a USB flash drive.
5
SFP1, SFP2
Ethernet optical
port
Connects to an ATB or another cascaded
SmartLogger.
6
ETH1, ETH2
Ethernet electrical
port
Connects to an Ethernet LAN switch, router or
PC device.
7
DO
Digital output (DO)
Relay output.
1
1
Overview
Port Description
1.2
1. The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents. However, all
statements, information, and recommendations in this document do not constitute a warranty of
any kind, express or implied.
2. Before installing the device, carefully read the
SmartLogger2000 User Manual
to get familiar
with the product information and precautions. SmartLogger is short for SmartLogger2000-10-B-
JP in the following text.
3. Install and use the device according to this document and the user manual. Otherwise, the
device may be damaged. Use insulated tools when installing the device.
4. This section describes the installation and cable connection operations using the SmartLogger
applied in the non-SmartACU2000 smart array controller (smart array controller for short)
scenario as an example.
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
Model
PLC (MBUS) Module
Configured?
Remarks
SmartLogger2000-10-B-JP
Yes
The built-in Bluetooth module supports
both Android APP and IOS APP.
Model Description
1.1