background image

– 16 –

◊  When the machine will not be used for a long time, it is suggested to turn off the controller 

 

  switch, and disconnect the power plug. Please note that the current timer setting may fail  

  (because it needs working with battery).  Reset it when you use the pump next time.

◊  Control board are not allowed to install in high-temperature places such as bathroom, so as 

 

  to prevent moisture from affecting the normal work .

◊  The temperature of water tank is set at 52ºC in factory. The higher water temperature you 

 

  set the lower energy efficiency ratio (cop value) it runs.
◊  If the first one or two timers are set and you want to set more, you need to delete them and 

 

  reset all of the timers.

◊  This machine has auto-self-sterilized function. This function will be activated when reaches 

 

  certain circumstances, even the machine is in stand-by status. The target water temperature 

 

  on the display will keep glittery during this function is on.

WARNING

◊  During the operation, when the evaporator coil’s temperature is lower to a certain extent, 

 

  the evaporator may be frost. At this time, the system will automatically defrost. After that, it  

  will recover and run automatically.

◊  The water produced by heat pump shall not be used as drinking water. Please add cool water 

 

  to the hot water before using, so as get the proper water temperature and avoid scalding.

ATTENTION

Please stop operation and unplug the machine if occurs the following circumstances. Contact 

our dealers or maintenance personnel and do not repair the heat pump water heater on your 

own, because wrong repair may cause casualties or fire.
● Fuses and protectors often disconnect.
● Power cord and power switch heat abnormally.
● Bad smell during operation.
● Leakage of the heat pump water heater.

PART 5: 

Repair and Maintenance of the Heat Pump Water Heater

When using the heat pump water heater, please check the unit’s operation regularly. If it can 

provide long-term and effective maintenance to the heater, the unit’s operation reliability and 

service span will be improved.

1. Clean the water filter regularly and make sure that the water within the system is clean, avoid 

 

  damages due to the water filter’s blocking.

2. All safety protection devices have been set correctly and completely in the factory, so please  

  do not adjust on your own.
3. The heat pump should be kept in clean and dry places with good ventilation so as to achieve  

  good heat exchange. Please clean the filter regularly according to different extent of the 

 

  environmental pollution.

4. To ensure the long-term work efficiency of the water heater, it is recommended to drain the 

 

  inner water out totally and clean one time every six months, remove accumulative sediment  

  during the operation.

Содержание HTW-AT-O-200VA1

Страница 1: ...USER AND INSTALLATION MANUAL HEAT PUMP WATER HEATER VA1 HTW AT O 200VA1 HTW ATS O 200VA1 Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Страница 2: ...e appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 In order to a...

Страница 3: ...s of Using the Heat Pump Water Heater 5 PART 3 The Installation of Heat Pump 7 PART 4 Instructions of Usage and Daily Operations of Heat Pump 14 PART 5 Repair and Maintenance of the Heat Pump Water He...

Страница 4: ...ndly This product consumes natural energy with no air pollution no smoke emissions and no harmful gas emissions It has zero pollutions and is absolutely environmental friendly Safe and Reliable This p...

Страница 5: ...e heater occurs dry burning and over high temperature phenomenon the protection devices will shut off immediately for protection PART 2 Cautions of Using the Heat Pump Water Heater Make sure to instal...

Страница 6: ...the connecting is reliable Note It is not allowed to disconnect or take apart the ground wire of power supply under any circumstances it is prevented to use damaged wires and switches You should repl...

Страница 7: ...line place If the machined is installed in the place vulnerable to rain it is essential to take the necessary measures to prevent rain and avoid rain erosion Please select the place where easily conne...

Страница 8: ...ut of the outlet You can switch on the heater after that The water quality should meet the following standards Hardness CaCO3 200milliliter liter Chloride ions 50 milliliter liter PH value 6 5 8 5 and...

Страница 9: ...Installation requirements of safety valve connection pipes Screw threads are G1 2 internal make sure the water can flow out of the safety valve and the water outlet part should be installed straight...

Страница 10: ...ent standards It should use all pole disconnection device which has at least 3 mm contact separation when connecting the power It needs double check the electrical circuit before connecting to the pow...

Страница 11: ...not When the safety valve is working please check if it can drain out water successfully There isn t any abnormal vibration or sound during the machine s operation 8 Technical Parameters Air source h...

Страница 12: ...ameters in the above table are only for reference When the contents of this table differ from those of the nameplate on the machine please refer to the nameplate The Relations of the Parts COP and the...

Страница 13: ...ecting Explanation Diagram for Model HTW AT O 200VA1 HTW ATS O 200VA1 ATTENTION This diagram is for reference only When the content of the above diagram differs from that on the machine please refer t...

Страница 14: ...lectrical assistance Note heat pump mode and assistant mode cannot be used at the same time When under automatic or heat pump mode the compressor has 3 minute starting delay protection function In ord...

Страница 15: ...e third timer finish For each timer setting it is required to set the turn on time first the timer indicator will be on During the setting please press the timer button to choose the data you want to...

Страница 16: ...the hot water before using so as get the proper water temperature and avoid scalding ATTENTION Please stop operation and unplug the machine if occurs the following circumstances Contact our dealers o...

Страница 17: ...whether the electrical components have any abnormal phenomenon or not If yes please ask your local dealer or contact us to replace and repair the machine 6 Please check whether the safety valve of wa...

Страница 18: ...de protection rod new anode rod threads need to be coated with suitable screw sealant and place the groove joints in magnesium rod with original seals or new specification seals Finally assemble magne...

Страница 19: ...s probe is fallen off 3 The sensor s wire is short circuit 1 Repair the wire 2 Fix the sensor probe again 3 Repair the wire and then rule out the breakdown E3 Coil temperature sensor failure open or s...

Страница 20: ...he reason and solve it accordingly 2 Replace the contractor 3 Find out the loose point and fix it 4 Identify the reason of overheating and then turn on the machine after trouble shooting The compresso...

Страница 21: ...continuously that means the drain valve loses efficacy You should stop using the heat pump and replace the drain valve as soon as possible 2 The duration for heating a whole tank s water becomes longe...

Страница 22: ...g information 1 Product s name model number and purchase date 2 Detailed information about the malfunction 3 Your contact information including address and name According to the national regulations o...

Страница 23: ...23...

Страница 24: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com...

Отзывы: