  F4: the temperature of suction;

  F5: the status of compressor; 0 means compressor off, 1 means compressor on.

  F6: the status of fan motor; 0 means motor off, 1 means motor runs at low speed, 2 means 

 

  motor runs at high speed;

  F7: the status of four-way valve; 0 means four-way valve off, 1 means four-way valve on.
(3) Temperature Setting of Water Tank

When the machine is on, you can adjust the temperature of water tank by pressing ▲ or ▼ 

button, which makes the temperature increasing or decreasing by 1ºCThe highest temperature 

of “heat pump” mode is 52ºC, while the one of “automatic” mode and “assistance” mode is 

both 70ºC.
(4) Clock Setting.

When the power is on, press the clock button for a long time and enter into the clock setting 

status. You can adjust the current data by pressing ▲ or ▼ button. Press the timer to choose 

the one you want to adjust and “minutes” and “hours” will flash in the time zone by returns. You 

can adjust the “minutes” with pressing ▲ or ▼ button. After finishing setting, you can press 

the clock button again or wait for 30 seconds, and then the clock setting will switch to home 

page.

In the process of setting time, if you don’t press ▲ or ▼ button when the data flashing for more 

than 30 seconds, then the machine will automatically exit and maintain the current setting time.

(5 )Timer Function

In the home page, press the timer button once, then it will enter the timer setting status. You 

can adjust the glittery data on the display by pressing ▲ or ▼ button. The setting order will be 

as follows: the first timer→the second timer→the third timer→finish. For each timer setting, it 

is required to set the turn-on time first (the timer indicator will be on). During the setting, please 

press the timer button to choose the data you want to adjust, and it will show on the display 

as hours→minutes→temperature→hours. Press the timer button to set the turn-off time and 

temperature (the timer indicator will be off). Press the mode button one more time to confirm 

the data and finish the setting (only when the third timer is finished setting).

If you press the mode button for a long time during the setting, the data will not be kept and it 

will go back to the home automatically.
(6) Delete the Timer Records

During the setting, press the timer button for a long time until it goes back to the home page 

automatically, and then all the timer records will be deleted.
(7) Trace the Timer Records

Activate the display and press the timer button, and then enter the status to trace the timer 

records. Press mode buttons to change over different records.
Kindly reminder:

◊  You can select the time slot from 12 a.m. to 5 p.m. as the turn-on time to warm up the 

 

  machine, because the temperature will be higher and can absorb much heat, which  

  guarantees good working efficiency.
◊  It is suggested to choose off-peak power consumption and use the pump in the evening, 

 

  because most of the regions have cheaper electric charge for night.

◊  Choose the heating time and water temperature as needed, because there will be heat loss 

 

  though the heat pump has heat insulation function. Besides, long-time insulation will make 

 

  the machine keep running and consume more electricity.

◊  In normal use, open any one of water outlet exits will come out hot water, and cold water will 

 

  be refilled automatically.

Содержание HTW-AT-O-200VA1

Страница 1: ...USER AND INSTALLATION MANUAL HEAT PUMP WATER HEATER VA1 HTW AT O 200VA1 HTW ATS O 200VA1 Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Страница 2: ...e appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 In order to a...

Страница 3: ...s of Using the Heat Pump Water Heater 5 PART 3 The Installation of Heat Pump 7 PART 4 Instructions of Usage and Daily Operations of Heat Pump 14 PART 5 Repair and Maintenance of the Heat Pump Water He...

Страница 4: ...ndly This product consumes natural energy with no air pollution no smoke emissions and no harmful gas emissions It has zero pollutions and is absolutely environmental friendly Safe and Reliable This p...

Страница 5: ...e heater occurs dry burning and over high temperature phenomenon the protection devices will shut off immediately for protection PART 2 Cautions of Using the Heat Pump Water Heater Make sure to instal...

Страница 6: ...the connecting is reliable Note It is not allowed to disconnect or take apart the ground wire of power supply under any circumstances it is prevented to use damaged wires and switches You should repl...

Страница 7: ...line place If the machined is installed in the place vulnerable to rain it is essential to take the necessary measures to prevent rain and avoid rain erosion Please select the place where easily conne...

Страница 8: ...ut of the outlet You can switch on the heater after that The water quality should meet the following standards Hardness CaCO3 200milliliter liter Chloride ions 50 milliliter liter PH value 6 5 8 5 and...

Страница 9: ...Installation requirements of safety valve connection pipes Screw threads are G1 2 internal make sure the water can flow out of the safety valve and the water outlet part should be installed straight...

Страница 10: ...ent standards It should use all pole disconnection device which has at least 3 mm contact separation when connecting the power It needs double check the electrical circuit before connecting to the pow...

Страница 11: ...not When the safety valve is working please check if it can drain out water successfully There isn t any abnormal vibration or sound during the machine s operation 8 Technical Parameters Air source h...

Страница 12: ...ameters in the above table are only for reference When the contents of this table differ from those of the nameplate on the machine please refer to the nameplate The Relations of the Parts COP and the...

Страница 13: ...ecting Explanation Diagram for Model HTW AT O 200VA1 HTW ATS O 200VA1 ATTENTION This diagram is for reference only When the content of the above diagram differs from that on the machine please refer t...

Страница 14: ...lectrical assistance Note heat pump mode and assistant mode cannot be used at the same time When under automatic or heat pump mode the compressor has 3 minute starting delay protection function In ord...

Страница 15: ...e third timer finish For each timer setting it is required to set the turn on time first the timer indicator will be on During the setting please press the timer button to choose the data you want to...

Страница 16: ...the hot water before using so as get the proper water temperature and avoid scalding ATTENTION Please stop operation and unplug the machine if occurs the following circumstances Contact our dealers o...

Страница 17: ...whether the electrical components have any abnormal phenomenon or not If yes please ask your local dealer or contact us to replace and repair the machine 6 Please check whether the safety valve of wa...

Страница 18: ...de protection rod new anode rod threads need to be coated with suitable screw sealant and place the groove joints in magnesium rod with original seals or new specification seals Finally assemble magne...

Страница 19: ...s probe is fallen off 3 The sensor s wire is short circuit 1 Repair the wire 2 Fix the sensor probe again 3 Repair the wire and then rule out the breakdown E3 Coil temperature sensor failure open or s...

Страница 20: ...he reason and solve it accordingly 2 Replace the contractor 3 Find out the loose point and fix it 4 Identify the reason of overheating and then turn on the machine after trouble shooting The compresso...

Страница 21: ...continuously that means the drain valve loses efficacy You should stop using the heat pump and replace the drain valve as soon as possible 2 The duration for heating a whole tank s water becomes longe...

Страница 22: ...g information 1 Product s name model number and purchase date 2 Detailed information about the malfunction 3 Your contact information including address and name According to the national regulations o...

Страница 23: ...23...

Страница 24: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com...

Отзывы: