– 15 –
F4: the temperature of suction;
F5: the status of compressor; 0 means compressor off, 1 means compressor on.
F6: the status of fan motor; 0 means motor off, 1 means motor runs at low speed, 2 means
motor runs at high speed;
F7: the status of four-way valve; 0 means four-way valve off, 1 means four-way valve on.
(3) Temperature Setting of Water Tank
When the machine is on, you can adjust the temperature of water tank by pressing ▲ or ▼
button, which makes the temperature increasing or decreasing by 1ºCThe highest temperature
of “heat pump” mode is 52ºC, while the one of “automatic” mode and “assistance” mode is
both 70ºC.
(4) Clock Setting.
When the power is on, press the clock button for a long time and enter into the clock setting
status. You can adjust the current data by pressing ▲ or ▼ button. Press the timer to choose
the one you want to adjust and “minutes” and “hours” will flash in the time zone by returns. You
can adjust the “minutes” with pressing ▲ or ▼ button. After finishing setting, you can press
the clock button again or wait for 30 seconds, and then the clock setting will switch to home
page.
In the process of setting time, if you don’t press ▲ or ▼ button when the data flashing for more
than 30 seconds, then the machine will automatically exit and maintain the current setting time.
(5 )Timer Function
In the home page, press the timer button once, then it will enter the timer setting status. You
can adjust the glittery data on the display by pressing ▲ or ▼ button. The setting order will be
as follows: the first timer→the second timer→the third timer→finish. For each timer setting, it
is required to set the turn-on time first (the timer indicator will be on). During the setting, please
press the timer button to choose the data you want to adjust, and it will show on the display
as hours→minutes→temperature→hours. Press the timer button to set the turn-off time and
temperature (the timer indicator will be off). Press the mode button one more time to confirm
the data and finish the setting (only when the third timer is finished setting).
If you press the mode button for a long time during the setting, the data will not be kept and it
will go back to the home automatically.
(6) Delete the Timer Records
During the setting, press the timer button for a long time until it goes back to the home page
automatically, and then all the timer records will be deleted.
(7) Trace the Timer Records
Activate the display and press the timer button, and then enter the status to trace the timer
records. Press mode buttons to change over different records.
Kindly reminder:
◊ You can select the time slot from 12 a.m. to 5 p.m. as the turn-on time to warm up the
machine, because the temperature will be higher and can absorb much heat, which
guarantees good working efficiency.
◊ It is suggested to choose off-peak power consumption and use the pump in the evening,
because most of the regions have cheaper electric charge for night.
◊ Choose the heating time and water temperature as needed, because there will be heat loss
though the heat pump has heat insulation function. Besides, long-time insulation will make
the machine keep running and consume more electricity.
◊ In normal use, open any one of water outlet exits will come out hot water, and cold water will
be refilled automatically.