heater with an empty or partially empty tank (“dry firing”), or failures 

caused by operating the water heater when it is not supplied with 

potable water, free to circulate at all times.

16. Failure of the heater due to the accumulation of solid materials 

or lime deposits.

17. Any damages or failures caused by using any models other than 

SSU / SSU-C 80 and 119 gallon models in live steam applications.

18. Any damages or failures caused by live steam pressures in excess 

of 10 PSI in the indirect heat exchanger.

19. Any damage or failure resulting from improper water chemistry.  

WATER CHEMISTRY REQUIREMENTS (RESIDENTIAL USE) – Water pH 

between 6.5 and 8.5. Operating temperatures not exceeding 140

o

F. 

Hardness less than 12 grains (200 mg/L). Chloride concentration less 

than 100 ppm (mg/L). TDS less than 500 ppm (mg/L). (COMMERCIAL 

USE) - Water pH between 6.5 and 8.5. Hardness less than 7 grains (120 

mg/L). Chloride concentration less than 100 ppm (mg/L). TDS less 

than 500 ppm (mg/L).

20. Any damages, malfunctions, or failures resulting from the use of 

dielectric unions.

21. Production of noise, taste, odors, discoloration, or rusty water.

22. Water heaters replaced for cosmetic reasons.

23. Components of the water heater that are not defective, but must 

be replaced during the warranty period as a result of reasonable 

wear and tear.

24. Components of the water heater that are subject to warranties, 

if any, given by their manufacturers; HTP does not adopt these 

warranties.

25. Damages, malfunctions, or failures resulting from the use of any 

attachment(s) not supplied by HTP.

26. Water heaters installed outside the fifty states (and the District of 

Columbia) of the United States of America and Canada.

27. Water heaters moved from the original installation location.

28. Water heaters that have had their rating labels removed.

PROCEDURES FOR WARRANTY SERVICE REQUESTS

Any claim for warranty assistance must be made promptly. Determine 

if the water heater is “in-warranty” (that is, within the applicable 

warranty period) by reviewing a copy of the original sales receipt or 

warranty registration. The Owner must present a copy of the original 

sales receipt or warranty registration for a warranty service request.

If the water heater is “in-warranty”, contact the retailer from whom 

the water heater was purchased (or the installer) for assistance. 

Be prepared to provide the retailer or installer with a copy of the 

original receipt, complete model and serial numbers, and the date 

of installation of the water heater, in addition to explanation of the 

water heater problem.

Warranty coverage is subject to validation of “in-warranty” coverage 

by HTP claims department personnel. All alleged defective or 

malfunctioning components must be returned to HTP via the local 

distribution channels where original purchase was made. 

NOTE: Any 

components or heaters returned to HTP for warranty analysis 

will become the property of HTP and will not be returned, even 

if credit is denied.

 If all warranty conditions are satisfied, HTP will 

provide replacement components to the retailer.

For questions about the coverage of this warranty, please contact HTP 

at the following address or phone number: HTP, 272 Duchaine Blvd, 

New Bedford, MA, 02745, Attention: Warranty Service Department, 

1(800) 323-9651.

SERVICE, LABOR AND SHIPPING COSTS

 

This limited warranty does not extend to any shipping charges, 

delivery expenses, or administrative fees incurred by the Owner 

in repairing or replacing the water heater or component(s). This 

warranty does not extend to labor costs beyond the coverage 

specified in this warranty document. All such expenses are the 

Owner’s responsibility.

LIMITATIONS OF YOUR HTP WARRANTY AND REMEDIES

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND 

ACCEPTED TO THE FURTHEST EXTENT UNDER APPLICABLE LAW IN LIEU 

OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING 

WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE AND ANY OBLIGATION, 

LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER 

OR NOT ARISING FROM HTP’S NEGLIGENCE, ACTUAL OR IMPUTED. THE 

REMEDIES OF THE OWNER SHALL BE LIMITED TO THOSE PROVIDED 

HEREIN TO THE EXCLUSION OF ANY OTHER REMEDIES INCLUDING 

WITHOUT LIMITATION, INCIDENTAL OR CONSEQUENTIAL DAMAGES, 

SAID INCIDENTAL AND CONSEQUENTIAL DAMAGES INCLUDING, BUT 

NOT LIMITED TO, PROPERTY DAMAGE, LOST PROFIT OR DAMAGES 

ALLEGED TO HAVE BEEN CAUSED BY ANY FAILURE OF HTP TO MEET ANY 

OBLIGATION UNDER THIS AGREEMENT INCLUDING THE OBLIGATION 

TO REPAIR AND REPLACE SET FORTH ABOVE. NO AGREEMENT VARYING 

OR EXTENDING THE FOREGOING WARRANTIES, REMEDIES OR THIS 

LIMITATION WILL BE BINDING UPON HTP. UNLESS IN WRITING AND 

SIGNED BY A DULY AUTHORIZED OFFICER OF HTP. THE WARRANTIES 

STATED HEREIN ARE NOT TRANSFERABLE AND SHALL BE FOR THE 
BENEFIT OF THE OWNER ONLY.

NO OTHER WARRANTIES

This warranty gives the Owner specific legal rights. The Owner may also 

have other rights that vary from state to state. Some states do not allow 

the exclusion or limitation of incidental or consequential damages so this 

limitation or exclusion may not apply to the Owner.

These are the only written warranties applicable to the water heater 

manufactured and sold by HTP. HTP neither assumes nor authorizes 

anyone to assume for it any other obligation or liability in connection 

with said water heaters. 

HTP reserves the right to change specifications or discontinue models 
without notice.

Содержание SuperStor Ultra SSU-119

Страница 1: ...ult in substantial property damage severe personal injury or death HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Section 1417 NOTE TO CONSUMER PLEASE KEEP A...

Страница 2: ... state provincial and national codes laws regulations and ordinances Part 1 General Safety Information This water heater is approved for indoor installation only and is not intended for use as a pool heater Clearance to combustible materials 0 top bottom sides and back Heater must have room for service 24 front 6 top and 0 sides are recommended service clearances A combustible door or removable pa...

Страница 3: ...warranty High heat sources sources generating heat 100o F 37o C or greater such as stove pipes space heaters etc may damage plastic components of the water heater as well as plastic vent pipe materials Such damages ARE NOT covered by warranty It is recommended to keep a minimum clearance of 8 from high heat sources Observe heat source manufacturer instructions as well as local state provincial and...

Страница 4: ...eater must be installed vertical on a level surface NOTE In the State of California the water heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirements in your area Visit http www dsa dgs ca gov or call 1 916 445 8100 and request instructions However applicable local codes shall govern installation For residential water heaters of...

Страница 5: ...lp 83 Rev 006 Rel 005 Date 12 18 17 5 Figure 2 Dimensions ...

Страница 6: ...equired to achieve the listed first hour rating MODEL GROSS BOILER OUTPUT 140oF 90oF Δ T 127oF 77oF Δ T 115oF 65oF Δ T SSU 20 84 000 121 140 168 SSU 30 102 000 154 180 212 SSU 30LB 113 000 169 198 234 SSU 45 141 000 212 248 292 SSU 45C 215 000 314 367 414 SSU 60 174 000 266 311 370 SSU 60C 245 000 354 414 467 SSU 80 212 000 330 386 440 SSU 80C 331 000 490 573 647 SSU 119 269 999 423 495 564 SSU 11...

Страница 7: ...A 73 112 152 B 53 81 110 SSU 30 A 83 125 160 193 B 60 90 115 140 SSU 30LB A 84 128 166 213 B 60 92 120 154 SSU 45 A 94 138 180 210 242 B 68 100 130 152 175 SSU 60 A 221 244 251 258 266 287 305 B 160 176 181 186 192 207 220 SSU 80 A 297 305 314 367 424 489 503 B 216 223 230 269 311 359 370 SSU 119 A 333 384 444 457 470 543 627 645 B 216 251 290 335 345 399 460 474 C Reduced Boiler Input Sizing Guid...

Страница 8: ...he appliance it is still possible to have high TDS This water can be corrosive Consult local water treatment companies for other treatment solutions to reduce this affect NOTE To promote appliance service life it is strongly recommended to follow the maintenance procedures in this manual Part 3 Piping A Plumbing It is mandatory that all plumbing be done in accordance with federal local and state p...

Страница 9: ... and property damage serious injury or death may result RE INSPECTION OF T P RELIEF VALVES T P valves should be inspectedATLEASTONCEEVERYTHREEYEARS andreplacedif necessary by a licensed plumbing contractor or qualified service technician to ensure that the product has not been affected by corrosive water conditions and to ensure that the valve and discharged line have not been altered or tampered ...

Страница 10: ...3 11 77 12 24 12 7 13 1 10 GPM 10 25 11 1 11 95 12 8 13 66 12 GPM 11 3 13 2 14 1 15 16 14 GPM 15 3 16 4 17 5 18 6 19 8 Pressure Drop for Pipe Length of 1 1 4 Copper Six 90o Elbows and One Tee Pipe Size 20 30 40 50 60 20 GPM 10 9 11 7 12 6 13 4 14 3 22 GPM 14 15 16 17 18 24 GPM 16 2 17 5 18 8 20 1 21 5 28 GPM 20 4 22 23 6 25 2 26 8 Table 7 Pressure Drop through 1 and 1 1 4 Copper H Applications Fig...

Страница 11: ...ulators should have an integral flow check 4 Drains and check valve between heating appliance and water heater will assist in purging air from system 5 This drawing is meant to demonstrate system piping only The installer is responsible for all equipment and detailing required by local codes In Massachusetts you must install a vacuum relief valve per 248 CMR 6 Mixing valve application is optional ...

Страница 12: ... 3 All circulators should have an integral flow check 4 Drains and check valve between heating appliance and water heater will assist in purging air from system 5 This drawing is meant to demonstrate system piping only The installer is responsible for all equipment and detailing required by local codes In Massachusetts you must install a vacuum relief valve per 248 CMR 6 Mixing valve application i...

Страница 13: ...heck valve between heating appliance and water heater will assist in purging air from system 5 This drawing is meant to demonstrate system piping only The installer is responsible for all equipment and detailing required by local codes In Massachusetts you must install a vacuum relief valve per 248 CMR 6 Mixing valve application is optional but recommended to help prevent scalding See Part 3 Secti...

Страница 14: ...iler before starting any wiring procedures It is recommended that a disconnect switch be installed between the boiler control and the water heater Figure 16 Wiring with Circulators Figure 17 Wiring with Zone Valves C Wiring Diagrams CAUTION When wiring the water heater and controls be sure to label all wires to ease future maintenance Wiring errors can cause improper and dangerous operation CAUTIO...

Страница 15: ...g with Circulators R845A Relay Figure 19 Zoning with Circulators Using R8182D and DPST No Relay Required Figure 20 Zoning with Circulators Using L8124 A C and R845A Relay Figure 21 Zoning with Circulators Using L8124 A C and DPST Control No Relay Required ...

Страница 16: ...5A Relay Figure 24 Control with Built In DPST Switch No Relay Required Figure 22 Using L8148A or L8152A Cold Start Boiler Control with Circulators Figure 25 Zoning with Circulators Using L8124 E F and R845A Relay Figure 26 Zoning with Circulators Using L8124 E F and DPST No Relay Required ...

Страница 17: ...lp 83 Rev 006 Rel 005 Date 12 18 17 17 Figure 27 Priority Zone with Circulators Figure 28 Priority Zone with Zone Valves Figure 29 Using L8148A or L8152A Cold Start Boiler Control with Zone Valves ...

Страница 18: ...ng there are no leaks within the system flush the system to clear any soldering residue Many soldering fluxes contain Zinc Chloride which can corrode stainless steel Draw at least three times the volume of the water heater to properly flush the system 4 Initiate a call for hot water Ensure each zone valve or circulator operates only when its thermostat calls for heat Purge each zone of air to ensu...

Страница 19: ...e Replace if valve is blocked or does not operate properly NOTE TAKE CAUTION WHEN OPERATING RELIEF VALVE DISCHARGED WATER MAY PRESENT A SCALD RISK Drain Valve Open the drain valve and drain a few quarts of water from the bottom of the tank to flush any hard water deposits Replace if valve is blocked or does not operate properly NOTE TAKE CAUTION WHEN OPERATING DRAIN VALVE DRAINED WATER MAY PRESENT...

Страница 20: ...ir Trap in Loop Purge Air Not Enough Hot Water Zone valve restriction 1 full bore replace zone valve Circulator arrow reversed Reverse circulator Tank temperature too low Raise tank temperature Boiler temperature too low Raise boiler temperature Boiler sized too small Check sizing chart Tank sized too small Demand flow rate too high Install mixing valve Raise tank temperature Air trap in loop Purg...

Страница 21: ...rs utilized in heating applications that have been properly installed by qualified professionalsbaseduponthemanufacturer sinstallationinstructions G It is expressly agreed between HTP and the Owner that repair replacement or refund are the exclusive remedies of the Owner OWNER RESPONSIBILITIES The Owner or Qualified Installer Service Technician must 1 Have a relief valve bearing the listing marks ...

Страница 22: ...n warranty coverage by HTP claims department personnel All alleged defective or malfunctioning components must be returned to HTP via the local distribution channels where original purchase was made NOTE Any components or heaters returned to HTP for warranty analysis will become the property of HTP and will not be returned even if credit is denied If all warranty conditions are satisfied HTP will ...

Страница 23: ...te of Installation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the qualified installer service technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the qualified insta...

Отзывы: