background image

Overview 

This product is an infrared camera that integrates surface temperature 
measurement and real-time thermal image. The traditional inferred 
thermometer needs to measure every component one by one while it is not 
necessary for infrared imaging camera, thus saving time. The potential 
problems may be displayed on color display screen clearly. Moreover, the 
central point measurement cursor is used to locate quickly and accurately 
to measure the temperature of the target object.
In order to increase the differentiation, the product is provided with a visible 
light camera. The thermal images and visible images are stored in the 
device and can be read through USB or stored in a computer to generate a 
report or for print. 
With small volume, the product is easy to operate and has strong function. 
it is the ideal selection for electric power, electronic manufacturing, 
Industrial inspection and other fields.

Cleaning of the products 

Please use damp cloth or weak soap to clean the enclosure of the device. 
Don’t use abradant, isopropanol or solvent to clean. The lens and screen 
should be cleaned with use of cleaning agents for professional optical 
glasses.

Lens maintenance 

Prevent damage of the infrared lens

Clean the lens:

The following major functions increase the product’s accuracy and usability: 

The radiation coefficient may be adjusted to increase the measurement 
accuracy of objects with half reflection surface.
The highest temperature and lowest temperature cursor may guide the 
users to the areas with highest and lowest temperature of the thermal 
images.   
The selectable color palette. 

Clean the infrared lens carefully. The lens is provided with refined 
anti-reflection coating.
Don’t clean with force to prevent damage of the anti-reflection 
coating.The selectable color palette. 
Use a cleaning solution for lens maintenance, such as alcohol-based 
commercial lens cleaners, alcohol, and a lint-free cloth or paper towel. 
Compressed air tanks can be used to remove loose particles.

The compressed air tank or dry nitrogen ion gun (if applicable) may be 
used to blow the loose particles on the lens surface.
Dip the lint free cloth in alcohol.
Squeeze the excessive alcohol in the cloth or apply the lint free cloth on 
dry cloth lightly.
Wipe the lens surface by making circular motion. Then discard the cloth.
If it is necessary to repeat above step, please use new cloth to dip with 
the cleaning solution to wipe.

www.xintest.com.cn

9

www.xintest.com.cn

10

Содержание HT-A1

Страница 1: ...2 Yuhua Street Hongye Industrial Zone Tangxia Town Dongguan City Guangdong Province Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hytechcn com cn www xintest com cn www xintest en alibaba com Email kevin xintest com cn User Manual Version 1 2 Revised March 5 2019 HT A2 HT A1 ...

Страница 2: ...f image overlapping 1 2 Application of Image overlapping 2 Introduction to image sub menu 2 1 View image 2 2 Delete images 3 Introduction to color palette sub menu 3 1 Color palette description 22 23 24 25 26 27 27 29 27 27 27 30 28 23 3 2 Application of color palette 4 Introduction to emissivity sub menu 4 1 Emissivity description 4 2 Emissivity setting 4 3 The emissivity value of common material...

Страница 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Страница 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Страница 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Страница 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Страница 7: ... professional optical glasses Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Страница 8: ...nterface When the product is off you can charge www xintest com cn 11 www xintest com cn 12 Display screen Model HT A1 HT A2 Infrared image resolution Visible image resolution Field angle Shortest focus length Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette View option Storage medium File fo...

Страница 9: ...orage temperature Relative humidity Built in chargeable 1800 battery Micro USB 2 0 Selectable 5 minutes 20 minutes not power off automatically 140mm 80mm 28mm 208g 0 to 45 20 to 60 85 RH working time 2 3 hours Visible light camera Infrared imaging sensor Image capture key LED lighting lamp Micro USB Back 320X240 English Chinese Italian German Setting command Language Unit language dat time informa...

Страница 10: ...e screen area It will move with the movement of the lowest temperature The cursor displays red The temperature value is displayed at the central position of the screen www xintest com cn 15 www xintest com cn 16 On off key Menu key Selection key Entry key Navigation key Up down left and right The highest temperature cursor used to indicate the highest temperature position in the screen area It wil...

Страница 11: ...cessful the screen will display store photo prompt If yes is selected please press MENU key to determine to save the image If no is selected press SELECT ENTER key to determine not to save the image Image output The saved images through capture may be checked and output by connecting with a computer through Micro USB Read images Open the USB protective cover as shown in Use USB line to connect the...

Страница 12: ...t easier for users to understand the infrared images by using aligned visible images and infrared images The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly and share with other people more effectively 1 2 Application of Image overlapping Press the MENU button to enter the main menu and sele...

Страница 13: ... exit from the menu Spectra Iron Cool White Black Color palette The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide a...

Страница 14: ... less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivity will produce gia...

Страница 15: ...lack rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile Substance Thermal radiation Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar Brick Press MENU key to select the setting option in the main menu Press key again to enter the setting sub menu If you select self defined emissivity press the SELECT ENTER button to ent...

Страница 16: ...enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes As shown in the figure after selecting set time press in the navigation key to enter the setting time After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 24h Year Month Day Hou...

Страница 17: ...tion Then press SELECT ENTER key to determine selection After the setting is completed press key to return Press MENU key to exit from the menu Spot Off On 24h Failure phenomenon The thermal imaging device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new batt...

Страница 18: ...尺寸 9cm X 10cm 铜版纸 骑马钉 注意封面封底 必须对应首页跟尾页 ...

Отзывы: