Safety instruction

Considerations

Please ensure that you have read and understood the safety precautions
described in the following text before using the product so that you can 
operate it correctly.
The safety precautions described in the following text guides you to operate 
the product and its accessories correctly and safely to avoid damage and 
loss to you,other people and the device.

The warning describes the acts that may cause harm to users. Please 
observe the following operation in order to avoid electric shock or personal 
injury.

If the product case is damaged, don’t use it continuously.

Please contact the local distributors or agents of Xintai under such 
condition.

Warning: Don’t aim the laser pointer at human or 
animal's eyes.  The laser given out by the laser 
pointer may harm the vision.

Please observe the following guide in order not to damage the product:

Don’t assemble or dismantle the product without permission.

The product is a type of super precise equipment. Don’t try to dismantle,
assemble or remodel any part of the product. Repair of the product should 
be made by technical personnel designated by Xintai Company.

Avoid damage to probe of the product

Note: don’t put the product close to strong heat source directly (such as 
electric iron). Otherwise, it may damage the probe of the product.

Product hum

When the product works, there is light sound of clicking every several
seconds. This is normal phenomenon that the lens captures images.

Warning

During the process of use, if the product is found with smoke,
spark and the burnt smell, please stop using at once.

In case of such condition, the product power supply should be 
powered off first.After the smoke and peculiar smell disappears 
completely, please contact the local distributors or agents of Xintai.

Don’t remodel the adapter and the data line.

Otherwise, such remodeling may cause short circuit or fire.

www.xintest.com.cn

3

www.xintest.com.cn

4

Содержание HT-A1

Страница 1: ...2 Yuhua Street Hongye Industrial Zone Tangxia Town Dongguan City Guangdong Province Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hytechcn com cn www xintest com cn www xintest en alibaba com Email kevin xintest com cn User Manual Version 1 2 Revised March 5 2019 HT A2 HT A1 ...

Страница 2: ...f image overlapping 1 2 Application of Image overlapping 2 Introduction to image sub menu 2 1 View image 2 2 Delete images 3 Introduction to color palette sub menu 3 1 Color palette description 22 23 24 25 26 27 27 29 27 27 27 30 28 23 3 2 Application of color palette 4 Introduction to emissivity sub menu 4 1 Emissivity description 4 2 Emissivity setting 4 3 The emissivity value of common material...

Страница 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Страница 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Страница 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Страница 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Страница 7: ... professional optical glasses Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Страница 8: ...nterface When the product is off you can charge www xintest com cn 11 www xintest com cn 12 Display screen Model HT A1 HT A2 Infrared image resolution Visible image resolution Field angle Shortest focus length Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette View option Storage medium File fo...

Страница 9: ...orage temperature Relative humidity Built in chargeable 1800 battery Micro USB 2 0 Selectable 5 minutes 20 minutes not power off automatically 140mm 80mm 28mm 208g 0 to 45 20 to 60 85 RH working time 2 3 hours Visible light camera Infrared imaging sensor Image capture key LED lighting lamp Micro USB Back 320X240 English Chinese Italian German Setting command Language Unit language dat time informa...

Страница 10: ...e screen area It will move with the movement of the lowest temperature The cursor displays red The temperature value is displayed at the central position of the screen www xintest com cn 15 www xintest com cn 16 On off key Menu key Selection key Entry key Navigation key Up down left and right The highest temperature cursor used to indicate the highest temperature position in the screen area It wil...

Страница 11: ...cessful the screen will display store photo prompt If yes is selected please press MENU key to determine to save the image If no is selected press SELECT ENTER key to determine not to save the image Image output The saved images through capture may be checked and output by connecting with a computer through Micro USB Read images Open the USB protective cover as shown in Use USB line to connect the...

Страница 12: ...t easier for users to understand the infrared images by using aligned visible images and infrared images The use of image overlapping can capture the visible image of every infrared image so as to display the temperature distribution in the target region correctly and share with other people more effectively 1 2 Application of Image overlapping Press the MENU button to enter the main menu and sele...

Страница 13: ... exit from the menu Spectra Iron Cool White Black Color palette The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide a...

Страница 14: ... less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivity will produce gia...

Страница 15: ...lack rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile Substance Thermal radiation Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar Brick Press MENU key to select the setting option in the main menu Press key again to enter the setting sub menu If you select self defined emissivity press the SELECT ENTER button to ent...

Страница 16: ...enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes As shown in the figure after selecting set time press in the navigation key to enter the setting time After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 24h Year Month Day Hou...

Страница 17: ...tion Then press SELECT ENTER key to determine selection After the setting is completed press key to return Press MENU key to exit from the menu Spot Off On 24h Failure phenomenon The thermal imaging device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new batt...

Страница 18: ...尺寸 9cm X 10cm 铜版纸 骑马钉 注意封面封底 必须对应首页跟尾页 ...

Отзывы: