background image

Air quality detector

Instruction for use

Table of Content 
Product overview
Considerations
Product description
Function setting operation
Measurement
New air quality level
Install/replace battery
Product specification

- - - - - - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 6
- - - - - - - - - - - - - - - - - - 7

HT-9600

Содержание HT-9600

Страница 1: ...r Instruction for use Table of Content Product overview Considerations Product description Function setting operation Measurement New air quality level Install replace battery Product specification 1 1 1 4 5 6 6 7 HT 9600 ...

Страница 2: ... 2 Don t block or avoid strong air or hot air blowing to the air inlet for air sampling 3 Please use dry cloth to wipe the instrument case Don t use damp cloth or corrosive detergents 4 Don t dismantle and remodel the product without authorization Considerations Product description 1 Product structure and appearance description Case Temperature and humidity detection port Sampling air inlet LCD di...

Страница 3: ...ters press back to the main interface 2 At the mode of historical record when to change a parameter press exit from the change Function setting operation Function type Function items Function setting operation Historical record Page number Unit s place ten s place hundred s place Check historical record at the main interface press key to enter historical record mode press ENTER key and the current...

Страница 4: ...pen space before measurement to avoid blocking of the sensors Press the power key to switch on Press RUN key at the main interface and the instrument will enter the sampling state of 50 seconds At the moment do not operate the instrument first After completion of sampling the measurement result will be displayed on the display screen finally Users may enter Setting interface to set the particle un...

Страница 5: ...rrent Pumping type 20 Piece L ug m3 0 50 C 土1 C 0 99 RH 2 RH 10 50 C 10 90 RH 999 sets 2 minutes no key operation Concentration unit Temperature range Typical precision 6F22 9V battery 120mA Working current 200mA Display method Screen size Screen resolution Size Dimension 245 85 40mm 325g battery included 320 240 2 8 inches LCD value display Color backlight 8 Dongguan Xintai Instrument Co Ltd Add ...

Отзывы: