Product specification

Principle of PM2.5 Sensors
Sampling method
Light sources
Grain size channels
Flowrate
Measurement range
Resolution ratio
Test method
Sampling time
Sampling method
Typical precision

Humidity range

Optoelectronic type
Pumping type 
Laser diode 
0. 3um 2.5um 10 um
1L/min
0-1000ug/m3
1 ug
Manual
50s

Typical precision
Work temperature
Working humidity
Stored data
Automatic power off

Power supply
Startup current

Pumping type
<20%
Piece/L | ug/m3

50°C

1°C

99%RH

±2%RH
-10

50°C

10 

90%RH

999 sets
2 minutes(no key operation)

Concentration unit
Temperature range
Typical precision

6F22,   9V battery
120mA

Working current

200mA

Display method
Screen size
Screen resolution

 Size

Dimension

245× 85×40mm

325g (battery included)

320*240

2.8 inches

LCD value display. Color backlight 

-8-

Dongguan Xintai Instrument Co.,Ltd.

Add: Building F, No. 22 Yuhua Street, Hongye Industrial Zone, 
Tangxia Town, Dongguan City, Guangdong Province
Postcode:523710
Tel:+86-769-82612006
Fax:+86-769-82612005
Website:www.hytechcn.com.cn    
www.xintest.com.cn   www.xintest.en.alibaba.com

Содержание HT-9600

Страница 1: ...r Instruction for use Table of Content Product overview Considerations Product description Function setting operation Measurement New air quality level Install replace battery Product specification 1 1 1 4 5 6 6 7 HT 9600 ...

Страница 2: ... 2 Don t block or avoid strong air or hot air blowing to the air inlet for air sampling 3 Please use dry cloth to wipe the instrument case Don t use damp cloth or corrosive detergents 4 Don t dismantle and remodel the product without authorization Considerations Product description 1 Product structure and appearance description Case Temperature and humidity detection port Sampling air inlet LCD di...

Страница 3: ...ters press back to the main interface 2 At the mode of historical record when to change a parameter press exit from the change Function setting operation Function type Function items Function setting operation Historical record Page number Unit s place ten s place hundred s place Check historical record at the main interface press key to enter historical record mode press ENTER key and the current...

Страница 4: ...pen space before measurement to avoid blocking of the sensors Press the power key to switch on Press RUN key at the main interface and the instrument will enter the sampling state of 50 seconds At the moment do not operate the instrument first After completion of sampling the measurement result will be displayed on the display screen finally Users may enter Setting interface to set the particle un...

Страница 5: ...rrent Pumping type 20 Piece L ug m3 0 50 C 土1 C 0 99 RH 2 RH 10 50 C 10 90 RH 999 sets 2 minutes no key operation Concentration unit Temperature range Typical precision 6F22 9V battery 120mA Working current 200mA Display method Screen size Screen resolution Size Dimension 245 85 40mm 325g battery included 320 240 2 8 inches LCD value display Color backlight 8 Dongguan Xintai Instrument Co Ltd Add ...

Отзывы: