HTC 800 RX
Introduction
2.0
5
1.9
Vibration and noise
Warning!
Always use hearing protection when using the machine.
1.9.1
Hand and arm vibrations
Hand and arm-weighted vibration level [m/s²] for HTC 800 RX have been measured
using equipment approved in accordance with ISO 5349-1:2001. Measurement
uncertainty for the measuring equipment is given as +/- 2%.
The machine has been tested in accordance with ISO 5349-2:2001 and ISO 20643:2005
in order to identify the operations that contribute to the most frequent vibration
exposures. At vibration levels > 2.5 m/s², the exposure time should be limited in
accordance with the table below. For vibration levels > 5 m/s², immediate measures
must be taken by the employer to ensure that the exposure time does not exceed the
time specified in the table below.
Identified work conditions Measured values [m/s²] Daily permitted exposure
(number of hours)
Grinding/polishing
2.95
23
Floor preparation (T-rex)
3.7
14.6
1.9.2
Sound pressure and sound power level
This machine is tested for noise in accordance with ISO 3741 and ISO 11202 . For
information on the sound power level and sound pressure level for each model, see the
table in chapter Technical data, page
39
.