T2000-T2100
EN – 25
6. TECHNICAL SPECIFICATIONS
6.1. REFERENCE
CONDITIONS
Parameter Reference
condition
Environmental temperature
20°C
3°C
Relative humidity
50%RH
10%
Battery voltage
6V
0.5V
External magnetic field
<40A/m
External electric field
<1V/m
Clamp positioning
Horizontal
Position of the conductor in the clamp
Centred
Closeness to metal masses
> 10cm
Loop resistances
None
Measured sinusoidal current frequency
50Hz
Distortion percentage
<0.5%
Disturbance current in resistance measurement
None
6.2. TECHNICAL
CHARACTERISTICS
Accuracy is indicated as [% of r value] referred to the reference conditions.
Resistance
Range [
] Resolution
[
]
Accuracy
0.010
0.099
0.001
(1%rdg + 0.01
)
0.10
0.99
0.01
1.0
49.9
0.1
(1.5%rdg + 0.1
)
50.0
99.5
0.5
(2%rdg + 0.5
)
100
199
1
(3%rdg + 1
)
200
395
5
(6%rdg + 5
)
400
590
10
(10%rdg + 10
)
600
1000
20
(20%rdg + 20
)
If measured resistance is > 1000
, the display shows “OL”
Resistance measuring frequency: >1kHz
Measuring range of resistance alarm threshold setting: 1
999
TRMS AC Current (T2000)
Range Resolution
Accuracy
0.00mA
80.00mA
0.05mA
(2.5%rdg + 1mA)
80.0mA
650.0mA
0.5mA
(2.5%rdg + 2mA)
650.0mA
999.5mA
1.5mA
(2.5%rdg + 10mA)
1.000A
3.995A
0.005A
(2.5%rdg + 0.01A)
4.00A
20.00A
0.01A
(2.5%rdg + 0.02A)
Current measuring frequency: 50
60Hz
Measuring range of current alarm threshold setting: 1mA
999mA