2. GENERAL DESCRIPTION 

The digital solar power meter HT204 is used to measure the sunlight. Possible 
applications are the evaluation of the solar power in industrial installations (photovoltaic 
plants) or its danger level for people’s skin. The sunlight is usually expressed in W/m

2

 or 

BTU/(ft

2

*h). 

 

2.1. FEATURES 

 

Sunlight measurement up to 1999W/m

2

 / 634BTU/(ft

2

*h) 

 

High accuracy and rapid response 

 

DATA HOLD function to hold measuring values 

 

Unit and sign display for easy reading 

 

Measuring unit selection among W/m

2

 and BTU/(ft

2

*h) 

 

Manual scale selection 

 

Direct reading with no adjustments needed 

 

Maximum and minimum values 

 

Low battery indication 

 

2.2. INSTRUMENT DESCRIPTION 

 

LEGEND: 
 

1.  DATA HOLD active 
2. MAX active 
3. MIN active 
4. Decimal point 
5. Measured value 
6.  Measuring unit W/m

2

 

7.  Measuring unit BTU/(ft

2

*h) 

8. Low battery 

 

 

LEGEND: 
 
1. ON/OFF key 
2. M-H key to select the maximum, 

minimum or current reading 

3.  W/B key to select the measuring unit 

W/m

2

 or BTU/(ft

2

*h) 

4.  D-H key to hold displayed data 
5.  R key to select the full scale manually 

Fig. 1: Instrument description 

 

2.3.  DESCRIPTION OF FUNCTION KEYS 

2.3.1. ON/OFF 

key 

Press the 

 key to switch on and off the instrument. 

 

2.3.2. M-H 

key 

By pressing 

 key, maximum and minimum values are measured. The symbol 

corresponding to the desired function is displayed: “MAX” for maximum value, “MIN” for 
minimum value. To exit this function keep M-H key pressed for at least 1 second. 
 

Содержание HT204

Страница 1: ...Copyright HT ITALIA 2012 Release EN 1 01 09 02 2012 ENGLISH User s manual...

Страница 2: ...5 R key 4 3 PREPARATION FOR USE 4 3 1 Initial 4 3 2 Power supply 4 3 3 Calibration 4 3 4 Storage 4 4 OPERATING INSTRUCTIONS 5 4 1 Measurement description 5 5 PREVENTIVE MAINTENANCE 5 5 1 General info...

Страница 3: ...to the instruction manual An incorrect use may damage the luxmeter or its components 1 1 PRELIMINARY Before turning on the instrument make sure that the battery is correctly installed Replace the bat...

Страница 4: ...um and minimum values Low battery indication 2 2 INSTRUMENT DESCRIPTION LEGEND 1 DATA HOLD active 2 MAX active 3 MIN active 4 Decimal point 5 Measured value 6 Measuring unit W m2 7 Measuring unit BTU...

Страница 5: ...em Make sure that all standard accessories mentioned in paragraph 6 3 1 are included Should you have to return back the instrument for any reason please follow the instructions mentioned in paragraph...

Страница 6: ...is is a precision instrument To guarantee its performances be sure to use it according to these instructions and keep it stored on suitable environmental conditions Do not expose it to high temperatur...

Страница 7: ...tery 9V type 6LR61 Low battery indication is displayed when the battery is low Battery life About 100 hours carbon zinc Display Characteristics 3 1 2 digit LCD 2000 counts with OL indication Sample ra...

Страница 8: ...ansit Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit auth...

Отзывы: