5.2.6 Mounting the head armature of the bushing (with draw lead bolt / detachable
conductor bolt)
Fig. 13: Draw lead bolt / detachable conductor bolt (1)
Item
Part
Item
Part
1
Second wave-form groove
3
Draw lead bolt / detachable conductor
bolt
2
First wave-form groove
The draw lead bolt is conical. If the end of the cone is flush with the clamping fitting with its
large diameter, then the first wave-form groove (2) is in the same position as the locking
screw.
►
As standard
, tighten the locking screw in the first wave-form groove (2).
The second wave-form groove (1) is located at a distance of 8 mm from the first wave-form
groove.
► If the conductor cable needs to be tighter, for tolerance reasons, then tighten the locking
screw in the second wave-form groove.
Range STARIS®-Sia+
33/53