User Manual Digital Shredder
DIGITAL
SHREDDER
24
0803
Recalibrating the Touchscreen of your Digital Shredder
Your Digital Shredder screen was calibrated at the factory and should never require recalibration. However, in the unlikely
event that it does, the following procedure will allow a user to access the calibration routine.
Turn the Digital Shredder OFF
*
Turn the Digital Shredder ON
*
As soon as the full screen DOD logo appears touch the screen for at least 5 seconds, which will activate the calibration
routine. Following the on screen instructions, enter the
fi
ve points by touching the cross hairs.
After the
fi
fth point is entered the screen will recalibrate and the application will load
Accessories For Your Digital Shredder
There are several useful accessories for your Digital Shredder, including a hard shell travel case, and a variety of personality
blocks for different drive interfaces and form factors.
Where To Get Help
Please visit HSM’s website to review The Digital Shredder’s Frequently Asked Questions page at:
www.digital-shredder.de
If you have a speci
fi
c technical question or need to report a problem with your shredder, please contact HSM’s Technical Sup-
port Team through
our forum at www.digital-shredder.de or
1.
our contact form (e-mail) at www.digital-shredder.de
2.
Speci
fi
cations
Voltage:
230 V AC
Current:
2.5A RMS @ 230 V AC
Watts:
575 W
Frequency:
47 - 63 Hz
Temperature Range:
Operating: 0 °C to 35 °C (32 °F to 95 °F)
Storage: -40 °C to 65 °C (-40 °F to 149 °F)
Relative Humidity:
Operating: 10 % to 90 % (non-condensing)
Storage: 5 % to 95 % (non-condensing)
Altitude (maximum):
Operating: -15,2 m to 3.048 m (-50 to 10.000 ft)
Storage: -15,2 m to 10.668 m (-50 to 35.000 ft)