Installation and adjustment
18
2020-07-22
FM 239 MuW Beta Type Z Rev.01
The limit switches must switch so that the base profile comes to a stop
immediately before the safety zone. The safety zone is factory-marked
on the unit by a band (3).
Procedure
1.
Connect the power to the limit switches.
2.
Slacken the bracket fixing screw (Figure 6).
3.
Run the base profile as far as the safety zone.
4.
Move the limit switch until it trips.
5.
Tighten the bracket fixing screw.
6.
Check the correct position of the limit switch: Move the base profile
manually and observe the switching operation.
If the braking distance is too short, repeat the set-up.
6.3
Mounting a drive unit
Make sure the direction of rotation of the external drive unit takes into
account the direction of the spindle or timing belt so that the limit
switches work correctly.
Ke
y
1
Safety zone
3
Carriage with positive and
negative directions from
reference point 0
2
Negative limit switch
4
Positive limit switch
Figure 7: Example of travel direction and limit switch configuration