Installation and adjustment
FM 239 MuW Beta Type Z Rev.01
2020-07-22
15
Mounting rails
Figure 4: Mounting rails (1)
The recommended maximum spacing between the mounting rails is
700 mm.
Procedure
1.
Attach the mounting rails (1) loosely in position (Figure 4).
2.
Align the linear unit axially.
3.
Tighten the mounting rails (1)
(for tightening torques see section 3).
6.2
Setting maximum travel
Serious injury may result if the transport carriers topple over.
If the base profile moves to its full extent beyond the safety zone, the
transport carrier mounted on it may break away or topple over. The
linear unit may be destroyed
During setup, observe the specified safety zone and set the limit
switches accordingly.
Electrical switches may only be connected by qualified electricians.
To stop the base profile promptly in the event of an emergency
stop, allow for adequate braking distance.
Содержание Beta 100-D-ASS