Electronic Floor Temperature Controller with Timer for Flush Mounting
6018
Setting range approx.
10 - 40 °C (Scale 1 to 4)
Mains voltage:
230 V ~ ± 10% , 50 Hz
Switching current (max.) approx.
12 (4) A
Switch temperature differential:
0.7 K
Temperature sensor:
NTC to DIN 44574
length approx. 2 m, Ø approx. 8 mm
Perm. ambient temperature:
- 10 to + 40 °C
Connection cables:
2.5 mm
2
Energy class:
IV = 2.0%
Application area
The electronic controller is used for regulating the floor temperature of individual rooms. Application areas include
electrical heaters (direct heating, area heating, tempering systems, heating mats etc.) and hot water heaters.
Function
The device is equipped with a timer. This enables one or two heating times a day, such as a heating time from 6:00 to 22:00 for a
living room, or from 6:00 to 9:00 and from 17:00 to 22:00 for a bathroom. The reduced heating times with the setback temperature
are in between. The required floor temperature can be set between 10 and 45 °C at any time during operation and the setback
temperature is programmed. The timer can be deactivated (push down right slide switch towards the sun symbol), so that the
device regulates the temperature constantly at the heating temperature set on the setting dial (continuous operation). The heating
can be disconnected from the mains supply on one pole (push left slide switch down towards the blank circle). The clock will
continue to run. The red LED is lit as long as the controller has switched on the heating.
The device is supplied with the following
factory settings
:
Setback temperature
15 °C
Start 1st heating time
6:00 each day
End 1st heating time
22:00 each day
No second heating time
.
Working days are Monday to Friday
Rest days are Saturday and Sunday
If the device is to run with the factory settings, it is only necessary to enter the values for time and weekday (see overleaf).
The controller operates in
Block mode.
In this mode, the same time program runs on the weekdays and only has to be entered
once. A different time program can be entered for the rest days. Operating in only two blocks considerably reduces the amount of
programming required.
Connecting and commissioning
ATTENTION
: Work on the 230 V mains supply must only be carried out by authorised electricians. When connecting the device,
the safety regulations of the VDE (German Association for Electrical, Electronic & Information Technologies) and the local utility
companies must be observed. “Normally closed” valves are required for controlling hot water heating.
Mounting
: The temperature controller is mounted in a standard Ǿ 55 mm conduit box (to DIN 49073, part 1). When using
additional intermediate terminals, use of a deep conduit box is recommended. The device is connected according to the circuit
diagram below. The connection cables must be straight and must be stripped by approx. 5 mm. Mounting height approx. 1.5 m
above the floor. Attention! Fit the support ring above the wallpaper and mount the controller on the conduit box using the self-
tapping screws. Then place the caps on the two slide switches, fit the cover on the conduit box and screw the cover tight. Finally fit
the setting dial (align with the groove) to the device.
The floor temperature sensor must be laid in a protective tube at heating
mat level in the centre between the heating mats. The sensor cable must
be laid in a separate protective tube and must not be laid together with the
power supply cables. Attention: Avoid electric shock. Be aware that in the
event of a fault, the power supply may be present on the sensor line. After
the power supply is switched on, it is advisable to press the Reset button
(countersunk on the right of the LED).
L N PE
TAN
TA (not assigned)
Heating
Floor temperature sensor
L
L
N
1