background image

FH12 Series

0.5mm and 1mm Pitch Connectors For FPC/FFC

Top Contact Type

Operation

Precautions

1. FPC/FFC Termination procedure.

Connector installed on the board.

1) Lift up the actuator. Use thumb or index finger.

2) Fully insert the FPC/FFC parallel to mounting

surface, with the exposed conductive traces
facing UP.

3) Rotate down the actuator until firmly closed.

It is critical that the inserted FPC/FFC is not
moved and remains fully inserted. Should the
FPC/FFC be moved, open the actuator and
repeat the process, starting with Step 1
above.

2. FPC/FFC Removal

1) Lift up the actuator.
2) Carefully remove the FPC/FFC.

FPC/FFC conductive traces

Stiffener

FPC insertion area

1) Avoid further lifting of the actuator once the lock has

been released. Doing so will cause the lock lever to
separate from the rotational shaft, and the lock lever
will become disengaged or the hook portion of the
connector body will be damaged.

2) Avoid further pressing of the lock portion from

the locked condition when the FPC/FFC has
not yet been inserted. Doing so will cause the
lock lever to become disengaged from the
rotational shaft, and the hook portion of the
connector body will be damaged.

3) Do not insert the FPC/FFC diagonally. D o i n g

so will result in the corners of the FPC/FFC
catching on the contacts and will cause defor-
mation of the contacts.

4) When closing down the actuator apply equal

pressure to both sides of the actuator.

actuator

Rotational shaft

19

Содержание FH12 Series

Страница 1: ...he lock lever is open Doing so will cause the lock lever to become disen gaged or will damage the hook portion of the connector body 4 When inserting the FPC FFC do not forcefully rub against the surface beneath the connector insertion slot Doing so will result in the FPC FFC forcefully striking the contacts and this will cause contact deformation peeling of the FPC FFC conductors and other irregu...

Страница 2: ...or able engagement of the lock lever in which the lock lever is raised To correct this first remove the FPC FFC and then reinsert it Forcing the lock will damage the connector 7 When locking handle the FPC FFC so that a load is not applied to the FPC FFC as would occur by pulling the FPC FFC or lifting it etc When a load is applied in the opposite direc tion to the rotational movement of the lock ...

Страница 3: ...uctive traces Stiffener FPC insertion area 1 Avoid further lifting of the actuator once the lock has been released Doing so will cause the lock lever to separate from the rotational shaft and the lock lever will become disengaged or the hook portion of the connector body will be damaged 2 Avoid further pressing of the lock portion from the locked condition when the FPC FFC has not yet been inserte...

Страница 4: ...ithout the FPC FFC inserted 3 Do not insert the FPC FFC diagonally Doing so will result in the corners of the FPC FFC catching on the contacts and will cause deformation of the contacts Actuator upright FPC FFC conductive traces Stiffener Slot 3 Press down the actuator in the direction shown 2 FPC FFC Removal Rotate the actuator upward and withdraw the FPC FFC 2 Do not attempt to open or over rota...