Troubleshooting 

14 

 

IF THE COMPRESSOR IS NOT WORKING: 

Check 

Possible Reason 

Solution 

1.  Check for power. 

Compressor is not receiving power. 

Check the power outlet or 

electrical cord. 

2.  GFCI circuit tripped. 

Damage to electrical cord or low 

voltage from power supply. 

Contact a qualified electrician for 

professional assistance. 

3.  GFCI circuit not tripped. 

GFCI malfunction. 

4.  Poor connection with the 

capacitor. 

Wiring loosened or was damaged 

during the shipment. 

Contact HQUA or local dealer for 

repair/replacements. 

5.  No capacitor wiring issue can 

be observed. 

Bad capacitor. 

IF THE COMPRESSOR IS WORKING : 

ISSUE 

Check 

Possible Reason 

Solution 

No bubbles at any 

diffusers 

No air leaks detected, the 

compressor running louder 

and possible excessive 

vibration. 

Compressor air filter is 

dirty/dogged. 

Clean or replace air filter. 

Do not wet the filter!

 

No bubbles at some 

diffuser plates. 

Check for leaks at all 

connection in line. If none 

are audible, carefully spray 

LITTLE

 soapy water onto 

connections and look for 

bubbles. 

Vibration loosened 

connection or cracked 

fitting. 

Tighten loose connection 

or replace cracked fitting 

as necessary. 

Are all flow control valves in 

compressor wide open? 

Improper “balancing” of 

diffusers. 

Adjust air flow valves on 

main unit until all 

diffusers operate 

properly. 

Large rolling bubbles 

instead of fine bubbles at 

surface above one or more 

diffuser plates. 

Inspect each diffuser plate 

for malfunction. 

Diffuser membrane 

damaged, diffuser plate 

fitting broken or diffuser 

plate is flipped over. 

Contact HQUA or local 

dealer for 

repair/replacement. 

Air coming out of pressure 

relief valve. 

Inspect diffuser plates and 

tubing for clogging. 

Clogging. 

Remove any overgrowth 

around diffuser 

membrane surface. 

Nothing clogging. 

Bad pressure relief 

valve. 

Contact HQUA or local 

dealer for 

repair/replacement. 

Compressor stops working 

for periods of time, then 

starts. 

Inspect the ventilation 

condition for compressor. 

Compressor 

over-heating due to bad 

ventilation. 

Make sure the room is 

ventilated. 

Try to low down the 

temperature of it. 

Содержание PAS20

Страница 1: ...HQUA Instruction Manual for Pond Aeration System HQUA PAS20...

Страница 2: ...2...

Страница 3: ...13 2 1 System Components 2 2 Specifications 2 3 Installation 2 4 Initial Start up Seasonal Operation Section 3 Maintenance 13 3 1 Replacement Parts Section 4 Troubleshooting 14 Section 5 After Sales...

Страница 4: ...Keep the compressor ventilated cool and dry Do not allow anything to rest on the power cord Never attempt any maintenance function that is not specified in the user manual Never operate the system if...

Страница 5: ...Components 1 High efficiency continuous duty rocking piston compressor 2 Rubber compressor mounts reduce noise and vibration for silent operation 3 4 5 ft Electrical cord with a 3 pin plug 4 Airflow m...

Страница 6: ...r s stability 3 8 100 ft lead free airline is made of durable PVC composite Fish hook resistant and kink free Use from the compressor to diffuser and the connector kits are needed for the connection 2...

Страница 7: ...General Information 7 2 3Installation Tool Required Rake Boat Raft Swimsuit 7 8 Wrench Shovel Phillips screwdriver Coast Guard approved life jacket...

Страница 8: ...General Information 8...

Страница 9: ...General Information 9...

Страница 10: ...General Information 10...

Страница 11: ...ll be located Gently release the diffuser into the water Repeat until all diffusers are in position Complete backfill on airline trenches and level with a rake Complete installation by reviewing and f...

Страница 12: ...er of day Day 4 Run system for 4 hours turn system off for remainder of day Day 5 Run system for 8 hours turn system off for remainder of day Day 6 Run system for 16 hours turn system off for remainde...

Страница 13: ...g system and refer servicing to a qualified electrician when cord is damaged or frayed compressor power control compressor fan or other electrical components are producing unusual noises or odors Noti...

Страница 14: ...none are audible carefully spray LITTLE soapy water onto connections and look for bubbles Vibration loosened connection or cracked fitting Tighten loose connection or replace cracked fitting as necess...

Страница 15: ...an Check for clogged air filter Air filter in need of replacement Clean or replace air filter Do not wet the filter Section 5 After Sales Service If you need any support or have questions about the sy...

Отзывы: