background image

Maintenance 

13 

 

• Disconnect compressor and the ariline. 

• Cover airline ends with the caps or cloth to prevent debris from entering airline. 

• If operating during the winter season, condensation could cause airlines to freeze. If so: 

• Use 1 cup isopropyl alcohol in the airline running out to each diffuser plate. 

• Turn on compressor to push through line and free any ice blockage. 

Section 3    Maintenance 

 

HQUA PAS20 Aeration Systems are designed for low-maintenance and require minimal 

scheduled maintenance. Keep the room cool, dry and ventilated for the compressor. 

• Always unplug system before performing any maintenance or troubleshooting. 

• Always unplug system and refer servicing to a qualified electrician when: cord is 

damaged or frayed, compressor, power control, compressor fan, or other electrical 

components are producing unusual noises or odors. 

Notice

: Local environmental conditions may require more frequent maintenance. 

 

WARNING: Compressors are equipped with a thermal overload switch. If temperature 

becomes high enough to trip the overload, the compressor will shut down. It will then 

automatically start up when temperature decreases as long as power is applied. 

 

3.1 Replacment Parts 

 

EVERY 3-6 MONTHS – Air Filter: Clean/replace air filter HQUA-AF11. 

Pressure  Relief  Valve:  Check  to  ensure  air  is  not  escaping  from  valve  and  replace  if 

needed. 

EVERY 24-36 MONTHS – Membrane Sticks: We recommend inspecting and/or cleaning 

the membrane diffuser sticks every 24-36 months. 

 

Section 4    Troubleshooting

Содержание PAS20

Страница 1: ...HQUA Instruction Manual for Pond Aeration System HQUA PAS20...

Страница 2: ...2...

Страница 3: ...13 2 1 System Components 2 2 Specifications 2 3 Installation 2 4 Initial Start up Seasonal Operation Section 3 Maintenance 13 3 1 Replacement Parts Section 4 Troubleshooting 14 Section 5 After Sales...

Страница 4: ...Keep the compressor ventilated cool and dry Do not allow anything to rest on the power cord Never attempt any maintenance function that is not specified in the user manual Never operate the system if...

Страница 5: ...Components 1 High efficiency continuous duty rocking piston compressor 2 Rubber compressor mounts reduce noise and vibration for silent operation 3 4 5 ft Electrical cord with a 3 pin plug 4 Airflow m...

Страница 6: ...r s stability 3 8 100 ft lead free airline is made of durable PVC composite Fish hook resistant and kink free Use from the compressor to diffuser and the connector kits are needed for the connection 2...

Страница 7: ...General Information 7 2 3Installation Tool Required Rake Boat Raft Swimsuit 7 8 Wrench Shovel Phillips screwdriver Coast Guard approved life jacket...

Страница 8: ...General Information 8...

Страница 9: ...General Information 9...

Страница 10: ...General Information 10...

Страница 11: ...ll be located Gently release the diffuser into the water Repeat until all diffusers are in position Complete backfill on airline trenches and level with a rake Complete installation by reviewing and f...

Страница 12: ...er of day Day 4 Run system for 4 hours turn system off for remainder of day Day 5 Run system for 8 hours turn system off for remainder of day Day 6 Run system for 16 hours turn system off for remainde...

Страница 13: ...g system and refer servicing to a qualified electrician when cord is damaged or frayed compressor power control compressor fan or other electrical components are producing unusual noises or odors Noti...

Страница 14: ...none are audible carefully spray LITTLE soapy water onto connections and look for bubbles Vibration loosened connection or cracked fitting Tighten loose connection or replace cracked fitting as necess...

Страница 15: ...an Check for clogged air filter Air filter in need of replacement Clean or replace air filter Do not wet the filter Section 5 After Sales Service If you need any support or have questions about the sy...

Отзывы: