VDP5001RGBLD5
V. 02 – 17/09/2012
6
©Velleman nv
7.3
DMX Mode
This mode allows you to control the fixture by any universal DMX controller.
•
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This digital start address is the channel number from which the device starts to “listen” to
the DMX controller. The same starting address can be used for a whole group of devices or an
individual address can be set for every device.
•
When all devices have the same address, all the units will “listen” to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set individual addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
•
In case of the 5-channel VDP5001RGBLD5, you will have to set the start address of the first unit to 1
(CH1~5), the second to 6 (1 + 5) (CH6~10), the third to 11 (6 + 5) (CH11~15), and so on.
•
Use DIP switches
[9]
1 – 9 to specify the DMX address:
Address DIP
switches Switch Represents
5
1 1
2 2
3 4
19
4 8
5 16
6 32
40
7 64
8 128
9 256
To select a light pattern
1.
Set channel 1 between 102~152.
2.
Select a pattern with channel 2. The device has 20 patterns. Some examples:
DMX value
Laser pattern
0-11
12-23
24-35
Etc.
To select a program
1.
Set channel 1 between 153~203.
2.
Select a program with the other channels. The options are:
Channel
DMX value
Control Programs
CH1
0-50 Sound
control
51-101 Auto
102-152
Laser pattern mode (pattern can be selected with channel 2)
153-203
Control mode (programs can be selected with channels 2, 3, 4 or 5).
204-255 No
output
The effects with channel 1 in control mode (153-203) are:
Channel
DMX value
Control Programs
CH2
0-255
X axis rotation from anticlockwise – stop (128) – clockwise
CH3
0-255
Y axis rotation from anticlockwise – stop (128) – clockwise
CH4
0-41 White
42-83
Red
84-125 Green