Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
-40-
HD3Z Series User Manual V1.2
Ref. Code
Function Description
Setting Range [Default]
F06.11
Multi-frequency command 12
F00.09 - Upper limit
frequency [5.00Hz]
F06.12
Multi-frequency command 13
F00.09 - Upper limit
frequency [5.00Hz]
F06.13
Multi-frequency command 14
F00.09 - Upper limit
frequency [5.00Hz]
F06.14
Multi-frequency command 15
F00.09 - Upper limit
frequency [5.00Hz]
6.2.8
F08: Asyn. Motor Parameters
Ref. Code
Function Description
Setting Range [Default]
F08.00
Rated power of motor
0.2 - 500.0kW
[Depend on model]
F08.01
Rated voltage of motor
0 - 999V [Depend on model]
F08.02
Rated current of motor
0.1 - 999.9A
[Depend on model]
F08.03
Rated frequency of motor
1.0 - 400.0 [50.0Hz]
F08.04
Rated Rpm of motor
1 - 24000rpm
[Depend on model]
F08.00 - F08.04: Set rated value of motor according to motor nameplate.
F08.06
Parameter auto-tuning of motor
0 - 3 [0]
Note: F08.06 is enabled only in keypad control (F00.11 = 0).
0: No action.
1: Stationary auto-tuning.
2: Rotary auto-tuning.
3: Motor stator resistance measurement.
Steps:
1. Correctly set motor parameter (F08.00 - F08.04).
2. When F08.06 = 2, set proper Acc. time 1 (F03.01) and Dec. time (F03.02), free motor axis from load and
make sure it is safe.
3. When F08.06 = 1 or 2 or 3, press
, then press
to exit to parameter display state, and press
to start auto-tuning. LED keypad displays “Para auto-tuning”.
4. When run command flahses on keypad, it means auto-tuning is finished and return to stop state display,
and F08.06 resumes 0.
Содержание HD3Z Series
Страница 1: ...V1 2 2018 11 HD3Z Series Mining Inverter User Manual HD3Z Series Mining Inverter...
Страница 3: ......
Страница 4: ...Version and Revision Records Time 2018 11 Version V1 2 Revised chapter Revised contents V1 2 published...
Страница 5: ......
Страница 11: ......
Страница 15: ......
Страница 17: ......
Страница 83: ......