07/2017
HPML0574/C
LE08110AHC
Disclaimers
1. This product must be installed and used as per these instructions.
2. An IP rating of IP44 is generally considered suitable for external walls with supplementary protection such as overhanging eaves.
3. The IP rating of this product is only valid when installed on a flat and non-porous surface. Additional sealing may be required for irregular surfaces.
4. The fixing screws on this product should be tightened to a maximum torque of 0.8Nm. Over tightening may damage the product.
5. This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it should be discarded.
6. This product is not suitable for installation in hazardous and/or corrosive areas.
7. Electrical installations periodically receive transient over voltages. This product has been designed to minimise the effect of such voltages on connected
equipment. It may not give full protection for extreme over- voltage transients such as those resulting from a close lighting strike.
8. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property remains the property of
HPM Legrand in all cases.
9. HPM Legrand reserves the right to modify the specification of this product at any time.
10. This product has been designed to operate in ambient temperatures: -10°C to 45°C.
11. The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed.
Warranty
HPM Legrand warrants this product for a period of 5 years from the
date of purchase when used in accordance with these instructions
and considering the disclaimers listed herein.
These goods come with guarantees that cannot be excluded under
the Australian and New Zealand Consumer Laws. You are entitled to
a replacement or a refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired if the goods fail to be acceptable
quality and the failure does not amount to a major failure.
See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
wLegrand Australia
1300 369 777
www.hpm.com.au
HPM Legrand New Zealand
0800 476 009
www.hpm.co.nz
ABN: 31 000 102 661
PROBLEM
POSSIBLE CAUSE
SUGGESTED REMEDY
Light does not switch on when
there is movement in the
detection area.
1. No mains voltage.
Check all connections and fuses/switches.
2. Nearby lighting is too bright.
Redirect sensor or relocate the unit.
3. Controls set incorrectly.
Readjust sensor angle or control knob.
4. Sensor positioned in wrong direction.
Redirect sensor and/or adjust.
Light switches on for no apparent
reason. (False triggering)
1. Heat sources such as air con, vents, heater flues,
barbecues, other outside lighting, moving cars are
activating sensor.
Adjust direction of sensor head away from these
sources.
2. Animals/birds e.g. possums or domestic animals.
Redirecting sensor head may help.
3. Interference from on/off switching of electric fans
or lights on the same circuit as your floodlight. (This
problem does not always occur but a faulty switch
or noisy fluorescent light may cause the floodlight to
switch on).
Should the false trigger become troublesome, consider:
(a) Replacing a faulty switch.
(b) Replacing noisy fluorescent tubes or starters.
(c) Connecting the floodlight to a separate circuit
(In most cases where one or more of the above
suggestions have been carried out, false triggering
has been reduced).
4. From swimming pool reflection or reflective surface.
Redirect sensor.
Light remains on.
1. Continuously false triggered.
Redirecting sensor head may help.
2. Time is set too long.
Reduce time.
3. Floodlight is in MANUAL MODE.
Changes to AUTO MODE
Light switches on during daylight.
1. LUX control knob is set to daylight position.
Turn the LUX control knob to desired light setting.
When setting controls in daylight
the detection distance becomes
shorter.
1. Interference by sunlight.
Re-test at night.