background image

Plasterboard

1

2

Installation with wall box and 3m USB extension lead (EAUSBEXT3WE) for 770USB2PSXMWE / 770USB2PSXMBL

Mains cable

Brick wall

Wall cavity

0.8Nm

Mains cable

Plasterboard

Metal wall box 435 or plastic 

wall box 429R

USB extension lead 

EAUSBEXT3WE

Connect USB wires with 

corresponding mains cables.

Use junction box 404 or equivalent 

for mains wiring connection

USB driver

Connect mains cables to GPO

Ceiling

Insulation area

CLICK

Note

•  In application requiring the 3m USB extension lead, it shall not share the same conduit as the 240V a.c. 

mains wiring in accordance with the Wiring Rules. 

• The 3m extension lead is suitable for a standard Ø20mm conduit.

•  Do not cover this USB driver with insulating matting or similiar material under any circumstances.

Содержание 770USB2PSAMWE

Страница 1: ...ith USB mechanism stand alone in plate Connect USB module wires to the mains cable via insulated connectors 401 series as per diagram below 1 2 Features Installation Cat No 770USB2PSAMWE 770USB2PSAMBL 770USB2PSXMWE 770USB2PSXMBL Ouput 5V d c 5 4 8 A Input current 10A GPO 230 240V a c 50Hz Mains connections Via A and N wires Standby power consumption 0 07W Overload protection on output 5 1A NOTE US...

Страница 2: ...k wall Wall cavity Plasterboard 0 8Nm 1 Push assembled unit into the wall cavity 2 Screw the unit to wall with standard mounting accessories and then fix front plate Plasterboard Mains cable Wall cavity Cable tie box to Mains cable to avoid strain on USB mechanism Metal bracket Brick wall 0 8 Nm Brick wall Plasterboard Mains cable Wall cavity Cable tie box to Mains cable to avoid strain on USB mec...

Страница 3: ...h corresponding mains cables Use junction box 404 or equivalent for mains wiring connection USB driver Connect mains cables to GPO Ceiling Insulation area CLICK Note In application requiring the 3m USB extension lead it shall not share the same conduit as the 240V a c mains wiring in accordance with the Wiring Rules The 3m extension lead is suitable for a standard Ø20mm conduit Do not cover this U...

Страница 4: ...stant vibration temperature fluctuations or areas of high humidity This product contains no serviceable parts and no attempt should be made to repair this product If the product is faulty it should be discarded This product has been designed to operate in ambient temperatures 5 C to 40 C The material in this product may vary in colour from batch to batch Colour matching from one batch to another c...

Отзывы: