Item
Description
Status
9
Display*
Error codes are displayed in hexadecimal format, see
on page 58
for more information
10
UID button/LED (Drawer 1)
Blue = UID LED is enabled from the UID button
Blue flashing = System is in hard drive locate mode or an
enclosure firmware update is in progress
Off = UID LED is disabled
* If the GSI is amber, the system needs service. Activate the associated drawer UID button to view any
GSI error codes on the rear display.
IO module LEDs
IO module LED combinations
Blue
Green
Amber
Meaning
Off
Off
Off
No power
Off
On, solid
Off
Powered on and healthy, normal operation
Blinking
On, solid
Off
Locate IOM, not safe to remove
Blinking
Off
On, solid
IOM fault, not safe to remove
On, solid
On, solid
Off
Locate IOM, safe to remove
On, solid
Off
On, solid
IOM fault, safe to remove
IO module port LED combinations
Left LED
Right LED
Meaning
Off
Off
No power, fault or no cable installed
Off
Amber
Powered on with no SAS link or cable installed but broken
Green
Off
Powered on, link high speed
Green
Amber
Powered on, link high low
Display messages
This section describes error messages that the customer may be able to resolve. If an error message is
displayed that is not included below, contact HPE Support.
58
IO module LEDs