![HPE FlexFabric 12900 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/hpe/flexfabric-12900/flexfabric-12900_command-reference-manual_2175945050.webp)
45
Parameters
interface
interface-type interface-number
: Displays the MP information on a port specified by its port
type and port number. If this option is not specified, MP information on all ports is displayed.
Usage guidelines
The output is arranged by port name. On a port, the output shows MPs that serve VLANs, and then
shows MPs that do not serve any VLANs. The MPs that serve VLANs are displayed in the ascending
VLAN ID order. Within the same VLAN, the output is in the order of MIPs and MEPs (from high to low
level). The MEPs that do not serve any VLANs are displayed by level (from high to low).
Examples
# Display the MP information on all ports.
<Sysname> display cfd mp
Interface Ten-GigabitEthernet1/0/1 VLAN 100
MIP Level: 2 Service instance: 102
Maintenance domain: md_2
Maintenance domain index: 3
Maintenance association: ma_2
Maintenance association index: 3
MEP ID: 101 Level: 1 Service instance: 101 Direction: Inbound
Maintenance domain: md_1
Maintenance domain index: 2
Maintenance association: ma_1
Maintenance association index: 2
MEP ID: 100 Level: 0 Service instance: 100 Direction: Outbound
Maintenance domain: md_0
Maintenance domain index: 1
Maintenance association: ma_0
Maintenance association index: 1
Table 13 Command output
Field Description
Interface Ten-GigabitEthernet1/0/1
VLAN 100
MP configuration of VLAN 100 on the Ten-GigabitEthernet 1/0/1.
MIP
A MIP in the MP.
Level
MD level to which an MP belongs.
Service instance
Service instance to which the MP belongs.
Maintenance domain
MD to which an MP belongs.
Maintenance domain index
Index of the MD to which an MP belongs.
Maintenance association
MA to which an MP belongs.
Maintenance association index
Index of the MA to which an MP belongs.
Direction
Direction of the MEP, inbound or outbound.