4-26 AlphaServer 300 User’s Guide
Replacing the Battery
The battery supplies power to the real-time clock while the system is off. If you find that
when the system is powered on, the time is incorrect, you may need to replace the battery.
If this is necessary, replace the lithium battery with a Panasonic BR2032, CR2032, or
equivalent. After replacing the battery, you must reenter configuration and setup data
using the ARC or SRM console. Refer to Figure 4-22 when replacing the battery.
________________________ CAUTION ___________________________
If the battery is installed incorrectly, there is danger of explosion. Replace the
battery only with the same or equivalent type recommended by the
manufacturer. Discard used batteries according to manufacturer's instructions.
____________________________________________________________
MLO-009863
Figure 4-22 Replacing the Battery
1.
Gently pry the old battery from the battery holder.
2.
Insert the new battery, positive side up, into the holder.