background image

8/8/2014                                                        800 

WARNING:

  

The fire pit is designed to use approved media correctly installed over the burner to achieve proper combustion.

 

WARRANTY REQUIREMENT: 

Never install a mesh or screen under the media. 

IMPORTANT

Media affects flame pattern greatly.  It is possible to create an unusual flame pattern that could damage your  

enclosure.  Enclosure damage from an open flame fire feature is not covered under any warranty.  

 

Lava Rock & Glass Application

 

         

 Please follow the instructions below to add the finishing touch to your fire pit. Remember the deeper your lava rock or 

glass the more risk of reducing if not smothering the flame.   Particular attention needs to be on the pilot assembly area.   
Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition.    
Lava Rock Only Application 
1)

 

Install your fire pit per instructions.     

 
 
 
 
 
 
 

2)

 

Apply lava rock ONLY deep enough to cover ring and pan- 
less than 2” above fire ring. 

 

 
 

For Electronic Ignition

 

3)

 

Blow Out Box: Do not cover vents with lava rock- leave 
open. Do not allow any rock to block flame opening. 
 
  

 
 
 

 

  

 

 
 
 
 
 
 

4)

 

Blowout Box: Do not cover blowout box vents or 
opening with lava rock or glass.  Incorrect media 
installation will cause the pilot flame to suffocate and 
turn off pit or delay main burner ignition.                 

Decorative Glass Application 

1)

 

Install your fire pit per instructions. 

 
 
 
 
 
 

 

2)

 

Fill Pan with glass.  Cover Burner with 1/8 to ¼” of 
glass.  Do not over fill with glass.  All LP installations 
must be checked for back pressure with media installed.  
Failure to do so may result in personal injury or 
property damage. 

 

 

 
 

For Electronic Ignition

 

3)

 

  

Blowout Box: Do not cover blowout box vents or 

opening with lava rock or glass.  Incorrect media 
installation will cause the pilot flame to suffocate 
and turn off pit or delay main burner ignition.              

 
DO NOT COVER VENTS!      DO NOT COVER PILOT  
                                                             OPENING!   

 
 

Содержание Match Lit

Страница 1: ...vice or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANG...

Страница 2: ...ONTROL USE This family of product is not for use with any type of remote or start up timer control WARNING We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in ...

Страница 3: ...t or on adjacent wall to allow for emergency shutdown and maintenance Verify correct 110VAC or 24VAC Supply WARNING All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and maintenance WARNING Always use proper materials and construction for gas supply power and enclosure WARNING The enclosure must incorporate 1 vent on at least two o...

Страница 4: ...e Perform leak test on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply If using flex line avoid sharp bends with flex line to prevent whistling Turn on gas supply and perform leak test on all inlet connections Repair as needed For electronic ignition models hook up proper 110VAC or 24VAC electrical power following all local co...

Страница 5: ...cation 1 Install your fire pit per instructions 2 Apply lava rock ONLY deep enough to cover ring and pan less than 2 above fire ring For Electronic Ignition 3 Blow Out Box Do not cover vents with lava rock leave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to...

Страница 6: ...rner will be used indoors it is the installer s responsibility to follow all regulations local codes and achieve independent certifications WARNING Confirm Gas In is towards control valve or shutoff valve Installing backwards will result in severe gas leak and risk of explosion If your air mixer has an adjustment nut adjust to desire flame condition WARNING A pan must be used on LP systems and con...

Страница 7: ...aper clothing food material should be kept away from the fire pit Fire Pit is not for cooking Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location WARNING If lava rock is wet allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit WARNING ...

Страница 8: ...ential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If new install may take several attempts to purge air 2 Debris in gas line Confirm gas line is clear insulation dirt plastic excessive pipe sealer etc 3 Gas Pressure Improper Confirm proper gas pressure found Sect...

Страница 9: ...9 8 8 2014 800 ...

Страница 10: ...10 8 8 2014 800 ...

Отзывы: