Host Connection
32
Serial Transport
Baud Rate
Factory default: 9600
Specifies the connection speed in the range 110 to 115200 baud.
Parity
Factory default: None
This option specifies the parity mode for each transmitted character.
If the number of data bits specified by
Word Length
is
8
, set this
option to
None
.
Selecting
Odd
will cause an eighth bit to be added with a value of 1
if the previous 7 bits add up to an even number, and 0 if the previous
7 bits add up to an odd number. Selecting
Even
will cause an eighth
bit to be added with a value of 1 if the previous 7 bits add up to an
odd number, and 0 if the previous 7 bits add up to an even number.
Mark
parity will set every eighth bit to 1 and
Space
parity every bit
to 0.
Word Length
Factory default: 8
This option specifies the number of data bits sent for each transmit-
ted character.
Stop Bits
Factory default: 1
This specifies the number of stop bits sent for each transmitted
character.
Flow Control
Factory default: Both
This option specifies the type of flow control used by the line port to
communicate readiness to transmit or receive data from the host.
None
No flow control.
Input
XON/XOFF on received data.
Output
XON/XOFF on transmitted data.
Содержание TeemTalk Terminal Emulator 7.0
Страница 1: ...HP TeemTalk Terminal Emulator 7 0 User Manual ...
Страница 22: ...Introduction 6 Getting More Information ...
Страница 62: ...Keyboard Configuration 46 Compose Character Sequences ...
Страница 68: ...Mouse Functions 52 Defining a Macro ...
Страница 82: ...Editing Options 66 Clipboard Options ...
Страница 152: ...HP 700 92 96 Emulation 136 Setup Options ...
Страница 236: ...IBM 5250 Display Emulation 220 Setup Options ...
Страница 264: ...TA6530 Emulation 248 Setup Options ...
Страница 290: ...Capturing Host Communication 274 Replay File ...
Страница 302: ...Command Line Options 286 Emulation Workspace ...
Страница 340: ...Index 324 ...